Instruction Manual
4
Installation of Applicator
Installation of Tank, Mounting Brackets, and Drain / Fill Line
Locate the tank base bracket (001-4442U). This bracket will mount on the front of the baler is show below.
Depending on the year of the baler only two of the required three holes may be premade on the baler. Mark
and drill two 1/2” (13mm) holes (one per side) if necessary.
Be sure to check behind the area before drilling to ensure there is nothing that will be damaged. The bracket
will be secured on each side with three 1/2” x 1 1/4” hex bolts, six flat washers, three lock washers, and three
hex nuts. Secure the left side of the baler first. Slide the supplied shims (001-4442US), if necessary, between
the tank base bracket and the baler side wall if necessary. The shims need to be installed to prevent the balers
side wall from moving in once the tank base bracket hardware is tightened. Tighten all hardware.
Installation of Tank, Mounting Brackets, & Drain / Fill Line (continued)
Mount the tank on the tank base bracket (001-4442U) as shown below and on the previous page. The position
the tank and saddle so that the additional side hole on the tank will be facing the front of the baler. The tank
saddle will have four holes that will line up with point A. Use four 1/2” x 1 1/4” hex bolts, four flat washers, and
four lock washers to secure the tank to points A.
Locate parts bag 1 (PBA-1). The drain/fill line will connect to the tank at point C. Thread 3/4" elbow fitting (003-
EL3434) into end of tank. Run 3/4" hose from the elbow down the frame to the bottom of the baler. Drill 1/4"
(7mm) holes to accept the valve holder bracket and use 5/16” x 1 1/4” self-tapping screws. Connect valve
assembly to other end of hose. Place hose clamps on both ends. The drain/fill line needs to be used for all
filling or draining of the tank. Fill or drain from ground level only.
Valve bracket and
quick coupler
001-4442U
Front of Baler
A
C
B
A