Datasheet
00
.
06
Pin type
Level 3
Level 2
Level 1
Length for mating
Datum plane depth
Contacts for male connectors
HARTING offers 12 standard contact lengths for
har-bus
®
HM
male connectors: the standard mating
length of 8.2 mm, pre-leading contacts with 9.7 mm
and extra long contacts preferred for shielding
with 11.2 mm mating length. On the termination
side the standard length is 3.7 mm. With the three
termination lengths of 13.0, 14.5 and 16.0 mm even
for rear I/O applications different mating levels are
possible, depending on the pcb thickness and
shroud height.
The different contact lengths are designated with
letters to identify them in the configurations. For
special loadings please use the customer request
form at the end of this catalogue.
All contacts are offered with press-in termination
‘eye of the needle’. In accordance of the application
they can be delivered in performance level 1 or 2.
Circuit density
When using the recommended diameter of the
finished through hole (0.6 ± 0.05 mm) with an
appropriate annular ring, the remaining distance
between the rings is about 1 mm. Under the
condition that the width of the track and the space
between should be the equal, two tracks of 0.2 mm
width or three tracks of 0.14 mm width can be placed
between two rings. Typical designs are shown in the
drawing on the right side.
Contact dimensions [mm]