Datasheet

Han-Kit
®
Page 6
Han
®
4 A Metal Version
Part-Number
10 20 004 0001
10 20 004 0003
Dimensions in mm
Han-Kit
®
-4AGM
Hood Han
®
3 A straight
Bulkhead mounted hous.
1)
Han
®
3 A straight
Material Die cast zinc alloy
Protection degree
2)
IP 67
Cable gland M20, metal
Cable diameter 5 - 9 mm / 6 - 12 mm
Insert Han
®
4 A, 4-pins + PE
Screw terminal 1-2.5 mm², AWG 18-14
Electrical data accd. to DIN EN 61 984
3)
10 A 230/400 V 4kV 3
Rated current
Rated voltage
conductor-ground
Rated voltage
conductor-conductor
Rated impulse voltage
Pollution degree
Rated voltage
accd. to UL/CSA 600 V
Han-Kit
®
-4AWM
Hood Han
®
3 A straight
Bulkhead mounted hous.
1)
Han
®
3 A angled
Material Die cast zinc alloy
Protection degree
2)
IP 67
Cable gland M20, metal
Cable diameter 5 - 9 mm / 6 - 12 mm
Insert Han
®
4 A, 4-pins + PE
Screw terminal 1-2.5 mm², AWG 18-14
Electrical data accd. to DIN EN 61 984
3)
10 A 230/400 V 4kV 3
Rated current
Rated voltage
conductor-ground
Rated voltage
conductor-conductor
Rated impulse voltage
Pollution degree
Rated voltage
accd. to UL/CSA 600 V
Han-Kit
®
-4AWSM
Hood Han
®
3 A angled
Bulkhead mounted hous.
1)
Han
®
3 A straight
Material Die cast zinc alloy
Protection degree
2)
IP 67
Cable gland M20, metal
Cable diameter 5 - 9 mm / 6 - 12 mm
Insert Han
®
4 A, 4-pins + PE
Screw terminal 1-2.5 mm², AWG 18-14
Electrical data accd. to DIN EN 61 984
3)
10 A 230/400 V 4kV 3
Rated current
Rated voltage
conductor-ground
Rated voltage
conductor-conductor
Rated impulse voltage
Pollution degree
Rated voltage
accd. to UL/CSA 600 V
10 20 004 0005
Assembly cut out
bulkhead mounted
housing
22 x 22 mm
Assembly cut out
bulkhead mounted
housing
22 x 22 mm
1) Bulkhead mounted housing
with ange gasket
2) Protection degree acc. to DIN
EN 60 529 in locked position
3) For only use in grounded
circuits
Assembly cut out
bulkhead mounted
housing
22 x 22 mm