Datasheet
30
.
08
09 99 000 0198
09 99 000 0200
09 99 000 0220
09 99 000 0218
1)
2)
09 99 000 0219 09 99 000 0197
Tooling
Repair tooling ยท Instructions
Replacement of
single male
press-in contacts
Replacement of complete
press-in connectors
Lever up the moulding Remove the moulding Pull out a single male contact
Insert the new contact
into the cavity of the contact
using insertion tool
Correctly position
the new contact
and press-in by hand
Set up the moulding
with the press
1)
Termination support (see page 30.07)
2)
for 17 mm wrap posts
two termination supports are recommended
4.5 mm - 5.5 mm
13 mm - 13.2 mm 17 mm