Datasheet

02
.
20
Types
signal to 6 A
Technical characteristics Types F, FM, 2F and F9
Current carrying capacity
The current carrying capacity is limited by maximum temperature of
materials for inserts and contacts including terminals. The current
capacity curve is valid for continuous, non interrupted current loaded
contacts of connectors when simultaneous power on all contacts is
given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60 512
Fitting the crimp contacts
After crimping the wires onto the contacts with the help of a crimping
tool or an automatic crimping machine the contacts should be
correctly oriented and inserted into the cavities of the connector
moulding in the required configuration. They snap into position and
are firmly held in place. A light pull on the wire assures the correct
tensile strength of the contact. When using stranded wires with a
gauge below 0.37 mm² an insertion tool is necessary.
Removing the crimp contacts
The removal tool is inserted into a slot on the side of the respective
crimp cavity. This action compresses the contact retaining spring
therefore the contact can then be easily withdrawn using a light pull
on the wire. This action will cause no damage to the contact/wire
which can be repositioned/refitted as necessary. The drawing
demonstrates the crimp removal procedure (max. 5x).
Number of contacts
Type F 48, 32
Type FM 45
Type 2F max. 24
Type F9 max. 9
Contact spacing (mm)
5.08
Working current 6 A max.
see current carrying capacity chart
Clearance 1.6 mm
Creepage 3.0 mm
Working voltage
The working voltage also depends
according to the safety
on the clearance and creepage
regulations of the equipment
dimensions on the pcb itself
Explanations see chapter 00
and the associated wiring
Test voltage U
r.m.s.
1.55 kV (contact-contact)
2.5 kV (contact-ground)
Contact resistance 15 mfor wire wrap and
solder connections
20 m
including crimp connections
Insulation resistance 10
12
Temperature range – 55 °C … + 125 °C
The higher temperature limit includes
the local ambient and heating
effects of the contacts under load
Degree of protection for crimp terminal
IP 20
according to DIN 40 050
Electrical termination
Male connector
Solder pins for pcb
connections Ø 1 ± 0.1 mm
according to IEC 60 326-3
W
rap posts 1 x 1 mm
diagonal 1.34-1.45 mm
Crimp terminal 0.09-1.5 mm²
Female connector
Wrap posts 1 x 1 mm
diagonal 1.34-1.45 mm
Solder pins for pcb
connections Ø 1 ± 0.1 mm
according to IEC 60 326-3
Angled solder pins
1 x 1 mm for pcb
connections Ø 1.6 ± 0.1 mm
Solder lugs
Crimp terminal 0.09-1.5 mm²
Distributor
Crimp terminal 0.09-1.5 mm²
Insertion and withdrawal force
48 way 75 N
45 way 70 N
32 way 50 N
24 way 37 N
Materials
Mouldings Thermoplastic resin,
glass-fibre filled, UL 94-V0
Contacts Copper alloy
Contact surface
Contact zone: selectively gold-plated
according to performance level
1)
Termination zone: tinned
1)
Explanation of performance levels see chapter 00
Mating conditions see chapter 00
Coding systems see page 02.36
Mounting clips see chapter 00
Working current
Ambient temperature
Removal tool