Datasheet
01
.
10
Han
A
Han A
®
Han
®
3 A / 4 A
Han
®
10 A
Han
®
16 A
Technical characteristics
Current carrying capacity
The current carrying capacity is limited by maximum temperature
of materials for inserts and contacts including terminals. The
current capacity-curve is valid for continuous, not interrupted
current-loaded contacts of connectors when simultaneous power
on all contacts is given, without exceeding the maximum tempe-
rature.
Control and test procedures according to DIN IEC 60 512-3.
Specifications DIN VDE 0627
DIN VDE 0110
DINEN61984
Approvals , , SEV
Inserts
Number of contacts 3, 4, 10, 16, 32 (2 x 16) + PE
Electrical data acc. to DIN EN 61 984
Han
®
3 A, 4 A 10 A 230/400 V 4 kV 3
Working current
Working voltage conductor – ground
Working voltage conductor – conductor
Rated impulse voltage
Pollution degree
or 10 A 250 V 4 kV 3
Han
®
10 A, 16 A 16 A 250 V 4 kV 3
Working current
Working voltage
Rated impulse voltage
Pollution degree
– Pollution degree 2 also 16 A 230/400 V 4 kV 2
Working voltage
acc. to UL/CSA 600 V
Insulation resistance ≥ 10
10
Ω
Material Polycarbonate
Temperature range - 40
O
C … +125
O
C
Flammability acc. to UL 94 V 0
Mechanical working life
- mating cycles ≥ 500
Contacts
Material copper alloy
Surface - hard-silver plated 3 µm Ag
- hard-gold plated 2 µm Au over 3 µm Ni
Contact resistance ≤ 1 mΩ
Crimp terminal - mm
2
0.5 - 4.0 mm²
- AWG 20 - 12
Screw terminal
- mm
2
2.5 mm²
- AWG 14
- Tightening/test torque 0.5 Nm Han 10/16 A
0.25 Nm Han 3/ 4 A
Hoods/Housings thermoplastic Han
®
3 A / 4 A
Material Polycarbonate RAL 7032
Locking element Polyamide RAL 7032
Flammability acc. to UL 94 V 0
Hoods/Housings seal NBR
Temperature range - 40
O
C … +125
O
C
Degree of protection acc. to DIN
EN 60 529 for coupled connector IP 65
1)
Hoods/Housings metal
Material Han
®
3 A / 4 A die cast zinc
Material Han
®
10 A / 16 A die cast aluminium
Locking element Han
®
3 A / 4 A
steel, zinc plated
Locking element Han
®
10 A / 16 A
Han-Easy Lock
®
Hoods/Housings seal NBR
Temperature range - 40
O
C … +125
O
C
Degree of protection acc. to DIN
EN 60 529 for coupled connector
Han
®
3 A / 4 A IP 44
IP 65 with sealing screw
09 20 000 9918
Han
®
10 A / 16 A IP 65
further selection
of hoods/housings chapter 30 / chapter 31
Accessories
Crimping tools chapter 99
Cable clamps chapter 40
sealing screw chapter 40
Coding of Hoods/Housings chapter 40
Label acc. to CSA-approval chapter 40
Test connectors chapter 40
Working current
Ambient temperature
Working current
Ambient temperature
Working current
Ambient temperature
À
Wire gauge: 2.5 mm²
Â
Wire gauge: 1.0 mm²
Á
Wire gauge: 1.5 mm²
1)
without washer