Install Instructions

12
Type B Gas Vent - 3” to 12” Diameter
Installation Instructions
THESE INSTRUCTIONS SHOULD
REMAIN AVAILABLE TO THE
HOMEOWNER AT ALL
TIMES.
©2015 Hart & Cooley, Inc. All rights reserved Form No. 150952 12/15/2015 Printed in U.S.A.
Installation instructions for Hart & Cooley
UL-listed Type B gas vent adapters
The following table specifies the UL-listed adapters
to be used when changing between Hart & Cooley
and B-vent manufactured by others.
Othe
r
Ma
nuf
act
ur
er
Pip
e
D
i
ameter
Other
into
Hart & Co
ol
ey
Hart & Co
ol
ey
Vent
into
Selkirk LLC
Metal Fab, Inc.
American Metal
Products, Inc.
General Products
Company, Inc.
Simpson
Dura-Vent
3" - 6"
7" - 8"
3" - 6"
7" - 8"
3" - 6"
7" - 8"
3" - 6"
7" - 8"
3" - 6"
7" - 8"
RA or RPS
RA
RA or RPS
RA
RA or RPS
RA
RAA
RAA
RAA
RAA
RAA
RAA
RAA
RAA
RAA
Other into Hart & Cooley vent
Assemble
the female
end of the
adapter
over the
male end
of the other listed B-Vent. Fully seat the adapter or
provide a minimum of 1-inch overlap. Tighten the
screw in the slips provided. (See Figure 23.)
Hart & Cooley vent into Other
Insert “Other” female end’s
inner and outer inside RRA’s
inner and oute r. Slide
together minimum of 1 inch
to seat inner. Tighten the
screw. (See Figure 24.)
Figure 23
Figure 24
Table 4