Install Instructions

CEILING SUPPORT (10”)
The Model TLC ceiling supports are intended for
installation below both finished and unfinished ceilings.
The square firestop plate fits up against a ceiling, or
a joist opening framed level on all four sides. It is
adaptable to all types of chimney-connected appliances.
To start a vertical ceiling-supported chimney, simply
place a length of Model TLC pipe, at least 18 inches
long, in this support. See Figure 1.
Follow these steps to install.
1. Frame a level square opening (all four sides), such
that the inside dimensions are 6¼” larger than the
diameter (ID) of pipe being installed.
Note: The support must be underneath either the
framed opening or the finished ceiling.
DO NOT INSTALL SUPPORT ABOVE THE
FRAMING. See Figure 2.
2. Install finish ceiling material. Cut a circular opening
the same diameter as the framing dimension
(or square) through the ceiling inside the framed
opening, making it large enough to accept the
support. (With an existing ceiling, the opening
should be framed after cutting the hole.)
3. Place the support assembly up against the ceiling
opening from below.
4. Put one 8 penny common nail part way into each of
the four nailing areas of the assembly and check that
the plate is level and flush to the ceiling.
5. Finish nailing with 8 penny nails through all
prepunched holes.
6. Attach trim plate to ceiling or to framing at corners.
ATTACH CONNECTORS SECURELY AND OBSERVE
CLEARANCE TO COMBUSTIBLE MATERIAL.
The connector or smoke pipe is the sheet metal pipe
between the appliance and the chimney. Different
types of fuels and appliances have different connector
clearances to combustible walls and ceilings. These
clearances will be shown in the appliance instructions.
Hart & Cooley, Inc.
Installation Instructions
Read Sheet GS for important clearance and safety precautions before installing
any of the parts described in this sheet. Sheet GS is packaged with supports.
1
Covering - Ceiling Support & Connections
Sizes 10”
Model TLC
WARNING
Failure to follow these Installation Instructions could cause
FIRE, CARBON MONOXIDE POISONING, OR DEATH. If
you are unsure of installation requirements, call the phone
number listed on the back of these instructions.
Sheet
S-1
IMPORTANT: 10” is non-HT.