Order information: To order Hart & Cooley products, please contact any authorized Hart & Cooley distributor or call 800.433.6341. When you purchase Hart & Cooley products, you also receive the full support of Hart & Cooley technical and customer service. Technical and 800.433.6341 616.656.8200 800.223.8461 616.656.6399 customer service: toll-free phone toll-free fax fax Internet address: http: //www.hartandcooley.
Table of Contents Table of Contents MODEL TLC ALL-FUEL CHIMNEY INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 FLASHINGS AND STORM COLLARS ROOF FLASHING SELECTION CHART . . . . . . .13 STAINLESS STEEL CHIMNEY LENGTHS ADJUSTABLE FLASHING ASSEMBLY . . . . . . . .13 CHIMNEY SECTIONS . . . . . . . . . . . . . . . . . . . . . .3 TALL CONE FLASHING . . . . . . . . . . . . . . . . . . . .13 STAINLESS STEEL LOCKING BANDS . . . . . . . . .3 RUBBER BOOT FLASHING KIT . . . . . . . . . . .
Introduction Introduction MODEL TLC ALL-FUEL CHIMNEY Model TLC All-Fuel Chimney offers current technology in factory-built chimney design by providing superior performance, durability and safety. Certification & Applications Model TLC is safety-tested and listed to applicable UL safety standards for chimneys serving solid-fuel and liquid-fuel appliances. This includes UL 103. This chimney system is designed for use on appliances that use solid, liquid or gas fuels under natural draft conditions.
Stainless Steel Chimney Lengths Stainless Steel Chimney Lengths Chimney Lengths • Slim, advanced design allows for installation between 16" centers and still provides 2" clearance from combustible material. • Secure twist-lock design couples chimney sections together with just a 1/8 turn. Locking bands secure joints. • Includes locking band. • Sections overlap by 11/8". • Chimneys are sized according to the inner diameter and are available in 5" through 14".
Stainless Steel Elbows and Tees Stainless Steel Elbows and Tees NOTE: Chimney Offset Charts It may be necessary to offset the chimney in order to clear a joist or an obstacle. The three (3) charts on the following page will assist you in selecting the proper combination of elbow angle and chimney length(s) that will provide the necessary degree of offset within an available height. 1. Select the column with the proper chimney diameter of your system. 2.
Stainless Steel Elbows and Tees Stainless Steel Elbows and Tees Chimney Offset Charts Construction tolerances ± one inch 5
Stainless Steel Elbows and Tees Stainless Steel Elbows and Tees Insulated 15°, 30° and 45° Elbow Kits • The insulated elbow is used when offset is required. • Locking bands must be used on all elbows. • A maximum of 6 feet is allowable between offsets. • Elbow is fully insulated and can be used with the same 2-inch clearance as chimney lengths. • Elbow support must be used with all offset installations and will support 15 feet of chimney.
Insulated Tee with Tee Cap • The insulated chimney tee may be used for through-the-wall installation, using a wall support. • A chimney length is required to pass safely through a wall. • Includes the following: - Two locking bands - 5" to 8" sizes have an uninsulated (single-wall) twist-lock tee cap for non-wall support applications only. - 10" to 14" sizes have an insulated press fit tee cap.
Supports Adjustable Wall Support • Used to support the chimney on a through-the-wall installation. Supports • 5" to 8" sizes include top plate, side brackets, hardware, non-twist-lock insulated tee cap, and a long L-bracket to hold tee cap in place. • 10" to 14" sizes do not include the cap. Use tee cap packaged with tee.
Supports Ceiling Supports • For use in ceiling support installations. Model Number Dimensions (inches) Size A B 7 3 C 5" 16 /8 11 / 8 63/4 • Supports a total of 50 feet of chimney above. 6TLCCSR 6" 177/8 123/ 8 73/4 • Chimney pipe cannot pass below support. 7TLCCSR 7" 187/8 133/ 8 83/4 • Matte black finish with ceiling ring to cover rough opening. 8TLCCSR 8" 195/8 143/ 8 93/4 10" 181/2 161/ 4 101/4 10TLCCS Supports 5TLCCSR • Also acts as a firestop.
Supports Adjustable Roof Support • The roof support may be used on a floor, ceiling or roof, and adjusts to any roof pitch. Supports • It may be used above an offset to support the offset or as a supplementary support when the chimney height exceeds that of the primary support.
Shields Attic Insulation Shield Dimensions (inches) Model Number Size A B C 5TLCIS 5" 6TLCIS 6" 11 71/8 13 12 1 8 /8 14 1 7TLCIS 7" 13 9 /8 15 8TLCIS 8" 14 101/8 16 16 1 12 /8 18 18 1 14 /8 20 20 1 22 10TLCIS 12TLCIS 14TLCIS 10" 12" 14" 16 /8 Shields • The attic insulation shield must be installed where the chimney enters the attic space in any installation.
Shields Rafter Radiation Shield Dimension (inches) Model Number Size 5TLCRRS 5" 9 6TLCRRS 6" 10 7TLCRRS 7" 11 8TLCRRS 8" 12 Model Number Size A Shields • The rafter radiation shield must be installed immediately below the roof flashing, inside any enclosure. Black Wall Thimble • Used in a wall support installation. • Radiation shield is included with spacers, which maintain the mandatory 2-inch clearance to combustibles. • Attractive matte black finishing trim plate is included.
Flashings and Storm Collars Roof Flashing Selection Chart Flashings and Storm Collars To determine what roof flashing you’ll require, you must determine the pitch of the roof. To determine the pitch, you’ll need two rulers and a level. Measure the number of inches from the end of the level down to the roof. In this example, the pitch is 3/12. Adjustable Flashing Assembly - Flat to 6/12 Pitch • Used where the chimney passes through a roof with a pitch of Flat to 6/12. • Comes complete with storm collar.
Flashings and Storm Collars Rubber Boot Flashing Kit Flashings and Storm Collars • This kit fits 5", 6", 7" and 8" chimneys. • Required where the chimney passes through a corrugated roof. • Rubber boot flashing fits roof pitches up to 12/12. • Kit includes: Special Storm Collar Rubber Boot Spacer Kit Special Boot-Mounting Screws • UL-listed. Storm Collar • Used in conjunction with roof flashing to keep precipitation out.
Rain Caps Deluxe Rain Caps • Advanced design, premium quality stainless steel. • Provides protection against the elements. • Twist-lock connection for secure installation (10" to 14" has a slip-in connection).
Parts and Accessories Wall Band Parts and Accessories • Stainless steel construction. • Provides lateral support for the chimney when installed adjacent to a wall. • Maintains the mandatory 2-inch clearance to combustibles. • Used above the tee, then every 8 feet thereafter. Adjustable Ceiling Plate • Matte black finish. • Adjusts to multiple roof pitches. • Covers 2-inch space around chimney for attractive finish.
Parts and Accessories Stovepipe Adapter (stainless steel) • For quick and easy transition from black stovepipe to factory-built chimney. • Twist-lock for easy connection. • 5" to 8" is black. • Used where the chimney passes through a soffit to provide a finished appearance. • Maintains the mandatory 2-inch clearance to combustibles. • Does not act as a firestop. Matte Black Trim Collar • Used on wall support installations when passing through a noncombustible wall.
Parts and Accessories Adjustable Universal Roof Guy Kit Model Dimensions (inches) Number A • Used when more than 5 feet of chimney extends from the roof. • The kit includes two rods and an adjustable band. • Each rod extends to 4 to 6 feet. TLCRGK 7 to 16 Model Number Roll Size TLCSI 12" x 48" x 2" Parts and Accessories • The adjustable band will fit 5" to 14" size chimney. Shielding Insulation Wrap • Insulation for use with Attic Insulation Shield, Wall Thimble and Cathedral Ceiling Support Box.
Typical Installations Decorator Ceiling Support Installations Multi-Story Installation Wall Support Installation Cathedral Support Installation Typical Installations One-Story Installation Through a Soffit With Cathedral Ceiling Support Box 19
Limited Lifetime Warranty LIMITED LIFETIME WARRANTY Hart & Cooley, Inc. (“we,” “us,” “our”) warrants chimney and venting products to be free from defects in material and workmanship for as long as the original consumer owns the system. For products installed after January 15, 2007, for a period of ten (10) years from original installation, we will provide replacement product with a similar or like quality of available product, free of charge excluding any installation costs.
Check out other quality Hart & Cooley products... Form No. 010050 Form No. 010051 Form No. 851369 Form No. 851367 Form No. 851095 Form No. 010054 Form No. 851431 To order any of the above catalogs, please contact Customer Service toll-free at 800.433.6341.