Install Instructions
Type B Gas Vent - 3" to 12" Diameter
Installation Instructions
• If pipe assemblies are lowered into place from
above, sheet metal screws should be used to hold
the lock bands in place.
• Terminate the vent with a tall cone flashing (RTF),
storm collar (RS), and appropriate diameter cap.
Maintenance and inspection
Gas is a clean-burning fuel that typically does not
require maintenance of appliance vent system.
However, the liner must be inspected at least once a
year by a qualified inspector or installer at the same
time that the appliance is being inspected and
serviced. The cap snaps off for visual inspection of
the outlet area. Connector pipe should be removed to
examine the inlet at the base of the chimney. Look for
loose joints, debris, condensate or corrosion, and
clean or repair as required.
Combined vents
• For detailed instructions for combining two or more
appliances into a common vent, see the Gas Vent
Capacity Tables section in the application guide.
• Whenever possible, vents should be run directly
from collar of the appliance vertically out through
the roof in the most direct method available.
• In those cases where it is necessary or desirable to
combine the vent connectors of several gas-fired
appliances into a common vent, the vent connector
from each individual appliance should be arranged
to have as great a
vertical rise as
possible before
starting the lateral
run to the common
vent. If a
combined vent
cannot be used
because of
limitations in the connector rise or total vent height,
alternatives such as those illustrated (Figure 14)
may be used to secure greater rise or greater total
vent height. TYPE B GAS VENT CONNECTOR
must be used for Figure 14B.
Installation instructions for Hart & Cooley
UL-listed Type B gas vent adapters
The following table specifies the UL-listed adapters to
be used when changing between Hart & Cooley and
B-vent manufactured by others.
Other into Hart & Cooley vent
Assemble the
female end of
the adapter
over the male
end of the other
listed B-vent. Fully seat the adapter or provide a
minimum of 1-inch overlap. Tighten the screw in the
slips provided. (See Figure 15.)
Hart & Cooley vent into Other
Insert "Other" female end's inner
and outer inside RRA's inner and
outer. Slide together minimum of
1 inch to seat inner. Tighten the
screw. (See Figure 16.)
Other
Manufacturer
Pipe
Diameter
Other into
Hart & Cooley
Hart & Cooley
Vent into
Other
Selkirk Metalbestos/
Household Mfg. Co.
3" - 6"
7" - 8"
RA or RPA
RA
RRA
Metal Fab, Inc.
3" - 6"
7" - 8"
RA or RPA
RA
RRA
American Metal
Products, Inc.
3" - 6"
7" - 8"
RA or RPA
RA
RRA
General Products
Company, Inc.
3" - 6"
7" - 8"
RAA
RAA
RRA
Simpson Dura-Vent
3" - 6"
7" - 8"
RAA
RAA
RRA
THESE INSTRUCTIONS SHOULD
REMAIN AVAILABLE TO THE
HOMEOWNER AT ALL TIMES.
Figure 14
Figure 15
Figure 16