Rhein Tech Laboratories 360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com Client: M/A COM, Inc. Model: EDACS D3100 800 MHz Mobile Data Modem FCC ID: OWDTR-0037-E Standards: FCC Part 90/IC RSS-119 Report #: 2004178 APPENDIX K: MANUAL Please refer to the following pages.
Installation and Operator’s Manual MM21134 December-04 EDACS® D3100 RF Modem
REVISIO N - DATE December 2004 REASON FOR CHANGE Initial Release. M/A-COM Technical Publications would particularly appreciate feedback on any errors found in this document and suggestions on how the document could be improved. Submit your comments and suggestions to: Wireless Systems Business Unit M/A-COM, Inc. Technical Publications 221 Jefferson Ridge Parkway Lynchburg, VA 24501 or fax your comments to: (434) 455-6851 or e-mail us at: techpubs@tycoelectronics.
TABLE OF CONTENTS Page 1. RF ENERGY EXPOSURE INFORMATION............................4 1.1 RF ENERGY EXPOSURE AWARENESS, CONTROL INFORMATION, AND OPERATION INSTRUCTIONS FOR FCC OCCUPATIONAL USE REQUIREMENTS .....4 1.1.1 Federal Communications Commission Regulations..5 1.2 COMPLIANCE WITH RF EXPOSURE STANDARDS ....5 1.2.1 Mobile Antennas .......................................................6 1.2.2 Approved Accessories...............................................6 1.2.3 Contact Information.................
1. RF ENERGY EXPOSURE INFORMATION 1.1 RF ENERGY EXPOSURE AWARENESS, CONTROL INFORMATION, AND OPERATION INSTRUCTIONS FOR FCC OCCUPATIONAL USE REQUIREMENTS Before using your mobile two-way radio, read this important RF energy awareness and control information and operational instructions to ensure compliance with the FCC’s RF exposure guidelines.
exposure and provide simple procedures on how to control it. Please refer to the following websites for more information on what RF energy exposure is and how to control your exposure to assure compliance with established RF exposure limits. http://www.fcc.gov/oet/rfsafety/rf-faqs.html http://www.osha.gov./SLTC/radiofrequencyradiation/index.html 1.1.1 Federal Communications Commission Regulations Your M/A-COM, Inc.
CAUTION Table 1-1 lists the recommended minimum lateral distance from the AV102800V1 mobile antenna that must be provided for unaware bystanders in an uncontrolled environment, when the D3100 is transmitting at three watts. Transmit only when unaware bystanders are at least the uncontrolled recommended minimum lateral distance away from the transmitting antenna.
For a list of M/A-COM approved accessories refer to the product manuals, M/A-COM’s Products and Services Catalog, or contact M/A-COM at 1-800368-3277. 1.2.3 Contact Information For additional information on exposure requirements or other information, contact M/A-COM, Inc. at 1-800-528-7711 or at http://www.macomwireless.com.
2. SAFETY INFORMATION 2.1 COMMON HAZARDS The operator of any mobile radio should be aware of certain hazards common to the operation of vehicular radio transmissions. Possible hazards include: • Explosive Atmospheres Just as it is dangerous to fuel a vehicle with the motor running, be sure to turn the radio OFF while fueling the vehicle. Do not carry containers of fuel in the trunk of the vehicle when the radio is mounted in the trunk.
3. INTRODUCTION This manual describes how to program, install, and use the M/A-COM EDACS® D3100 Data RF Modem. The EDACS D3100 Data Modem is a data-only mobile or fixed-station radio used in the Enhanced Digital Access Communications System (EDACS) trunking environment systems. Table 2.
4. DESCRIPTION D3100 comes ready to connect into a system with a personality containing two systems. The power-on default system is an EDACS Data System named “Site” containing an EDACS Control Channel (806.075 TX/851.075 RX) and an EDACS Working Channel (820.975 TX/865.975 RX). The second system is named “851” and is a conventional system for use in parametric testing and calibration, should it be required.
4.1 DATA CONNECTOR FUNCTIONS The data connector on the D3100, in shape and form, is similar to the “option connector” of the E500M Mobile Radio made by M/A-COM. The following pinouts and drawing define the cable and connections. DATA CONNECTOR (J1) PIN ASSIGNMENTS (DB-25-Socket) (Pin # - Pin Function) 15. NC 1. NC 16. NC 2. GND 17. NC 3. IGN A+ (Not Used) 18. FPROG (Connect to A+ for Programming Mode) 4. NC 19. EXT_MIC_H 5. RQST 20. A+ (Connect to FPROG for Programming MPode) 6. Audio OUT 7.
5. OPTIONS AND ACCESSORIES Table 5-1: EDACS D3100 RF Modem Options and Accessories DESCRIPTION PART NUMBER D3100 Test Box TS103114V1 Roof Top Antenna AV102800V1 Yagi, 8dBd, Fixed-station Antenna AN103358V1 Control Unit, Orion, Scan, D2CP5L KRY 1011632/12 Data/Programming C-U Adapter Cable CA103067V1 Mounting Bracket Kit 19B802672P1 5.
Figure 5-1: Adapter Cable CA103067V1 13
6. INSTALLATION 6.1 UNPACK AND CHECK THE EQUIPMENT Before starting the installation, carefully unpack the equipment and inspect the equipment for damage. If there is any damage, file a claim with the carrier immediately. POWER CABLE DATA CABLE D3100 UNIT Figure 6-1: D3100 Unit 6.
To ensure the feasibility of the cable routes, it is suggested that the cables be run prior to installation of the radio. Ensure slack is left in each cable so the radio may be removed for servicing with all connections remaining intact. D3100 is intended for installation within a weatherproof building, enclosure, or vehicle. Typical installations are: 1. Elevated (usually beyond unassisted reach) in an outside enclosure with co-located antenna, 2.
6.4 D3100 DIMENSIONS 14 144 176 158 M4, 4 Holes 51 31.
7. WARRANTY A. M/A-COM, Inc. (hereinafter "Seller") warrants to the original purchaser for use (hereinafter "Buyer") that Equipment manufactured by or for the Seller shall be free from defects in material and workmanship, and shall conform to its published specifications. With respect to all non-M/A-COM Equipment, Seller gives no warranty, and only the warranty, if any, given by the manufacturer shall apply.
NOTES 18
NOTES 19
NOTES 20
21