User Manual

10515-0372-4000 7
Table 2-1: RF Exposure Compliance Tested Distances
The information in this section provides the information needed to make the
user aware of a RF exposure, and what to do to assure that this radio operates
within the FCC RF exposure limits of this radio.
Minimum Tested Distances Radio Frequency
Body Face
VHF-High (136–174 MHz) 0.47 in (1.2 cm)* 0.98 in (2.5 cm)
UHF-Low (380–520 MHz) 0.47 in (1.2 cm)* 0.98 in (2.5 cm)
700/800 MHz (762–800 MHz) 0.47 in (1.2 cm)* 0.98 in (2.5 cm)
* Note: This device complies with FCC RF Exposure requirements for body-
worn operations when used with the body-worn accessories tested and
approved for the Unity XG-100P. The body-worn accessory tested with the
minimum distance of 1.2 cm is the Harris Belt-Clip Part No. 12082-1291-01.
In order to comply with the FCC RF Exposure requirements for body-worn
operations, a minimum distance of 1.2 cm must be maintained from the back
of the radio to the user’s body using the Harris Belt-Clip Part No.
12082-1291-01 or other accessory tested and approved for the Unity XG-
100P.
2.2 ELECTROMAGNETIC INTERFERENCE
CAUTION
During transmissions, the XG-100P generates RF energy that
can possibly cause interference with other devices or systems.
To avoid such interference, turn off the radios in areas where
signs are posted to do so. Do not operate the transmitter in
areas that are sensitive to electromagnetic radiation such as
hospitals, aircraft, and blasting sites.
3 GENERAL SAFETY GUIDELINES
Do not crush, disassemble, reverse polarity, incinerate, or
mutilate the Lithium-ion battery. Do not expose the battery to
fire or temperatures above 158 °F (70 °C). The battery can
rupture or explode if it becomes hot, causing serious injury. If
a hissing sound is heard or an irritating smell occurs, move
equipment to a well-ventilated area.
If the battery pack is ruptured or is leaking electrolyte that
results in skin or eye contact with the electrolyte, immediately
flush the affected area with water. If the battery electrolyte gets
in the eyes, flush with water for 15 minutes and consult a
physician immediately.