User Manual

Table Of Contents
14221-1200-2000, Rev. A
27
4. Press (+) with a second time to set the group to Priority 2. is displayed.
5. Press (+) with
a third time to set the group to Priority 1. is displayed in column 1, line 1.
The priority level selection sequence only advances the group to the next higher priority level and
stops at priority level 1. To select a lower priority level, the group must be deleted from the scan list
and then added back to the scan list. Each new group added to the scan list starts at the lowest
priority. If the Priority 1 and Priority 2 groups are already set and a new group is assigned as Priority
1 or Priority 2, the previously assigned group changes to non-priority scanning.
6.19.3 Delete Groups/Channels from Scan List
1. With scan operation turned off, select the desired group/channel to delete from the selected trunked
system's group scan list.
2. Press (+) or (-) with
. The current scan status of the group is displayed for a time-out period.
3. Press (-) with
to delete the group from the scan list. , or turns off. Any group that is
not in a scan list shows a blank when it is the selected channel.
6.19.4 Nuisance Delete
A group or channel can also be deleted from the scan list, if it is not the currently selected group by
pressing (-) with
during scan operation while the radio is displaying the unwanted group or
channel. The group or channel is deleted from the scan list in the same manner as using the steps above.
Deletions performed in this manner do not remain deleted if the radio is turned off and then back on.
6.19.5 Turn Scan On
1. Toggle scan operation by pressing SCAN. The SCAN indicator turns on when the radio is
scanning.
2. When a group on the scan list receives a channel assignment, the radio unmutes on the assigned
channel, the BSY indicator comes on, and the received scan group is displayed.
The radio continues scanning if a new group is selected when scan is on.
Pressing the PTT button when scan is on causes the radio to transmit on the displayed group or on
the currently selected group depending on programming.
Pressing up with when scan is on causes the radio to recall the scanned group that was last
received. This group is recalled for a period equal to the scan hang time.
6.19.6 Priority Scanning
When scan is enabled and the Priority 1 and Priority 2 groups/channels have been identified, the radio
listens to calls on those groups/channels and the selected group/channel. While receiving a scanned call,
the radio continues to monitor the selected Priority 1 and Priority 2 groups/channels and drops the call if
the selected group/channel or other higher priority call becomes active. During a Priority 2 call the radio
continues to monitor for a Priority 1 call.
6.19.7 Turn Scan Off
Turn scan operation off by pressing SCAN. The radio resumes operation on the selected group.