User Manual

Table Of Contents
14221-1200-2010
65
SCREEN TEXT REASON RESOLUTION
Mission Plan In
Progress Screen
PLAN FAILED Mission plan activation failed.
Use RPM to ensure plan validity.
Contact Harris if failures persist.
Security Menu
ZEROIZE FAILED DSP could not zeroize
DSP problempower cycle the
radio and contact Harris if
problem persists.
NO KEYS TO ZEROIZE Key database empty. Nothing to zeroize.
Utilities Menu
INCORRECT
PASSWORD
Maintenance password invalid.
Enter a valid maintenance
password.
Channel Info Screen
INCORRECT
PASSWORD
Channel edit password invalid.
Enter valid channel edit
password.
10.2 OTAR ERRORS/INFORMATION
WORKAROUNDS:
1. Zeroize.
2. Load proper KEK from the Motorola KVL or Harris UKEK Loader.
IF RADIO INDICATES:
1. INVALID KEYSTORE ZEROIZE NEEDED:
This occurs if the radio’s keys were loaded by the Harris Key Loader followed by an attempt to load
UKEKs with the UKEK Loader or keys with the Motorola KVL. Fix by performing workaround 1,
followed by 2.
2. NO UKEK Displayed during a zeroize performed from the radio or a zeroize initiated from the
KMF.
- Fix by performing workaround 2.
3. Zeroize Complete – KMF has zeroized the radio.
- Fix by performing workaround 2.
4. Disabled OTAR Icon (red slash) OTAR is disabled while in scan, talkaround, emergency, and
monitor.
- Fix by disabling these features. Icon will be corrected (no red slash).
5. Gray OTAR Icon (no red slash) OTAR has not registered with tower (Conventional or Trunked
system).
- Fix by verifying proper frequencies.
- If the radio is turned to the OTAR channel out of range of a conventional tower, and then comes
in range after 3 minutes, fix by issuing an OTAR. Rekey, leaving and re-enter the OTAR channel.
6. Green OTAR Icon – OTAR is registered, all is well.
- If update fails, verify you are in range of the tower and the KEK is correct.
7. Blue OTAR Icon – OTAR is attempting to rekey.
- If rekey fails, verify you are in range of the tower and the KEK is correct.