User Manual
Table Of Contents
- 1. SAFETY SYMBOL CONVENTIONS
- 2. RF ENERGY EXPOSURE INFORMATION
- 3. OPERATION SAFETY RECOMMENDATIONS
- 4. OPERATING RULES AND REGULATIONS
- 5. INTRODUCTION
- 6. BASIC OPERATION
- 6.1 PROGRAMMING
- 6.2 XG-100M CONTROLS
- 6.3 DISPLAY
- 6.4 STATUS MESSAGES
- 6.5 ALERT TONES
- 6.6 BEFORE FIRST USE
- 6.7 POWER ON AND SET VOLUME
- 6.8 TURN ENCRYPTION ON OR OFF
- 6.9 USER INTERFACE PRIVILEGE LEVEL
- 6.10 SELECT CHANNEL USING MENUS
- 6.11 SELECT ZONE/SYSTEM USING MENUS
- 6.12 USE TALKAROUND TO BYPASS REPEATER (ANALOG AND P25 CONVENTIONAL)
- 6.13 INDIVIDUAL CALLS
- 6.14 SELECT A NEW TALKGROUP
- 6.15 SCAN OPERATION
- 6.16 VIEW GPS INFORMATION
- 6.17 EMERGENCY OPERATION
- 6.18 ENCRYPTION BAR
- 6.19 LIGHTS AND SIRENS
- 6.20 PUBLIC ADDRESS (PA)
- 6.21 SHORTCUT MENU
- 7. ADVANCED OPERATIONS
- 7.1 CREATE KEYS
- 7.2 LOAD KEYS
- 7.3 LOAD KEYGROUPS
- 7.4 ZEROIZE ALL FROM RADIO
- 7.5 ZEROIZE KEYS USING KVL 3000 PLUS
- 7.6 ZEROIZE KEYGROUPS USING KVL 3000 PLUS
- 7.7 ZEROIZE ALL FROM KVL 3000 PLUS
- 7.8 GLOBAL ENCRYPTION
- 7.9 SELECT KEYSET
- 7.10 OTAR CONFIGURATION
- 7.11 ACTIVATE/VIEW MISSION PLAN
- 7.12 CH INFORMATION MENU
- 7.13 EDIT CHANNEL (ANALOG AND P25 CONVENTIONAL ONLY)
- 7.14 SETTINGS MENU
- 7.15 SET UP SCAN
- 7.16 MESSAGE MENU
- 7.17 UTILITIES MENU
- 8. REFERENCE
- 9. GLOSSARY
- 10. BASIC TROUBLESHOOTING
- 11. TECHNICAL ASSISTANCE
- 12. WARRANTY
14221-1200-2010
34
10. Select Unity XG-100 Mobile from the drop-down and click Load.
11. After Key Loader displays a successful load, click Finish.
7.2.3 LOAD KEYS USING MOTOROLA KVL 3000 PLUS
Type 3 Digital Encryption Standard Output Feedback (DES-OFB) and Advanced Encryption Standard,
256-bit (AES-256), encryption methods are supported. The Type 3 Encryption keys are loaded via a
Motorola KVL 3000 Plus device using Telecommunications Industry Association (TIA)/Project 25 (P25)
key fill device protocol. Make sure that valid keys have been created and stored in the KVL 3000 Plus
before proceeding.
1. Power on KVL 3000 Plus.
2. Connect KVL 3000 Plus to XG-100M using cable 12099-0410-A1.
NOTE
Once the KVL 3
000 Plus is connected, a keyset is established whether the keys are
loaded or not. You will need to zeroize to bring the XG-100M to a fully zeroized state
(Section 7.4).
3. At the radio, select MAIN MENU SECURITY OTHER KEYFILL. The KEYFILL
SCREEN is displayed. The radio can now accept keys from the KVL.
At the KVL 3000 Plus:
4. Select TARGET.
5. Select LOAD.
6. Select KEY.