User's Manual
14221-1200-4010, Rev. B
14
2. SPECIFICATIONS
1
2.1 GENERAL
Dimensions (Height x Width x Depth):
XG-100LPA: 2.68 x 8.8 x 9.3 inches (6.81 x 22.4 x 23.6 centimeters)
(Includes bracket but not space required for cables)
XG-100LPA and XG-100M: 7.3 x 8.8 x 9.3 inches (18.5 x 22.4 x 23.6 centimeters)
(Includes bracket but not space required for cables)
Control Head, CH-100: 3.3 x 7.0 x 2.8 inches (8.4 x 17.8 x 7.1 centimeters)
(Does not include bracket and mounting screws)
Control Head, CH721: 2.4 x 6.9 x 3.9 inches (6 x 17.5 x 10 centimeters)
(Does not include bracket and mounting screws)
Weights
XG-100LPA and XG-100M: 13.6 pounds (6.17 kilograms), does not include bracket
Control Head, CH-100: 1.20 pounds (0.54 kilograms), does not include bracket
Control Head, CH-721: 1.25 pounds (0.57 kilograms), does not include bracket
Mounting Brackets: 1.25 pounds (0.57 kilograms) each
Cable, Interface: 1.25 pounds (0.57 kilograms)
Operating Ambient Temperature Range: -22 to +140° Fahrenheit (-30 to +60° Celsius)
Storage Temperature Range: -40 to +185° Fahrenheit (-40 to +85° Celsius)
Altitude
Operating: 15,000 feet (4572 meters) maximum
Storage/Shipment: 50,000 feet (15,240 meters) maximum
DC Supply Voltage Operating Range
For Full Performance: +13.6 Vdc ±10% (Normal range per TIA-603)
Overall Operating Range: +10.8 to +16.6 Vdc
Continuous without Damage: 0 to +17 Vdc
DC Supply Current (less control head and Unity mobile)
XG-100LPA
Receive: 1.1 amps maximum
Transmit at 30 Watts, VHF-Low: 7.25 amps typical, 10 amps maximum
Transmit at 100 Watts, VHF-High: 15 amps typical, 25 amps maximum
Quiescent/Off Current: 2 milliamps maximum
1
These specifications are primarily intended for the use of the installation technician. See the appropriate Specifications
Sheet for the complete specifications.