Instruction Manual

8
2.0 Technical Information
2.1 Specifications
2.1.1 Product Code
2.1.2 Operating Conditions and Environment
Temperature range:
+14° to +140°F (-10° to +60°C)
Relative Humidity:
85% or less
Noise Level:
92 dba maximum @ 1 meter when lifting rated load
95 dba maximum @ 1 meter when lowering rated load
Supply Air:
60 to 90 pounds per square inch
Air Consumption:
30 to 90 cubic feet minute
Air Lubrication Requirements:
Minimum 10 to 15 drops per minute (2-3 cc/min) of oil
Air Filtration Requirements:
Maximum 5 micron air filter or finer
Load Limiter:
Adjustable; Factory set to 125% of rated capacity