Instruction Manual

40
6.1.3 Dual Speed On dual speed models, the VFD has Count/Hour functions built into the parameters.
Refer to Table 6-2 for parameter identification. Refer to Table 6-3 for Count/Hour access procedure.
Table 6-2 VFD Count/Hour Parameter Identification
Parameter
Name
Discription
U7-01
Number of
Starts (Higher
Order)
The number of starts in the down direction x 1,000. Up to 10,000 units
are displayed.
Display of “1 = 1,000 starts.
Display of “10,000” = 10,000,000 starts
U7-02
Number of
Starts (Lower
Order)
The number of starts in the down direction under 1,000 starts (1 to 999).
One start will register a “1in the display. When 1,000 starts are reached,
the value of U7-01 is incremented by 1 and the value of U7-02 is reset to
0.
U7-03
Hours of
Operation
The number of hours of operation in both the up and down directions.
One hour will register a “1 in the display. Up to 65535 hours are
displayed.
The example using Table 6-2:
U7-01 displays “81”, U7-02 displays “567”, U7-03 displays “122”
Number of Starts (down) = 81,567
Number of Operated Hours = 122
Table 6-3 VFD Count/Hour Access Procedure
Operational Step
VFD Display
1. Energize the hoist.
2. Press until theMonitorscreen is displayed (blinking).
3. Press to display the parameter setting screen an then press to
move from 01to “U1”.
4. Press or until the display reads “U7” (left value blinking).
5. Press and or to select the specificMonitorparameter (right
vlaue blinking).
(Example: U7-03 Hours of Operation)
6. Press to display the current parameter value.
(Example: 75 Hours)
7. Press until the diplay returns to the initial screen.
(As in Step 1.)