Owner manual
7
3-90-70741R13_05/13
Top
Left Side
Front
Boiler
Cleaning Rod
Spring Handle
Hopper -
Sold
separately
Door
Blank
Adapter
Plate
Base Jacket
Base
Ash Tub
Ash Door
Right Side
Bafe
Flue Pipe
Clean out slide
Flue Plate
Hopper
Support
The VF3000 is reversible as to which end the hopper and
ue pipe are located. Therefore, a decision must be made
as to which way will work best for your situation.
If you woud like to have the ue to the right and the hopper
to the left, make sure the gaskets are in place on both the
ue pipe and ue plate. Bolt the ue pipe on the right end
and the ue plate on the left end of the base. Next, the bafe
must be slid into place on the right end with the center of the
base. Note the bafe and ue pipe must always be at the
same end and opposite the hopper.
Next, place the base jacket around the base and clamp into
place with the four clamping bolts on the front of the base.
The hole in the jacket goes around the ue pipe.
Place 1/4” x 1” gasket around the at edge on top of the
base. Now place the boiler on top of the base with the feeder
opening opposite the ue pipe. Place 1/4” x 1” gasket around
the door openings on the boiler. Bolt the door mount on the
front door opening with 5/16” x 1” at head bolts. Bolt the
door blank on the rear opening with 5/16” x 1” hex head bolts.
Now the outer jacket can be installed. The front jacket with
the coil hole must be installed rst. Next, the two sides which
hold the front in place and then the top which holds the sides
in place.
Assembly