Manual

Table Of Contents
RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
C AU TION :
IN PU T POW ER
40W M AX
230VAC~50Hz
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
CAUTION: Chassis surface hot.
WARNING: To reduce the risk of fire or electric shock,
do not expose this equipment to rain or moisture.
AVIS: Risque de choc electricque ne pas ouvrir.
ATTENTION: Superficie de chassis chaude.
1. AC Line Cord
Technical Specifications:
Back Panel:Front Panel:
Rated Power
40W RMS @ 4 ohms
Frequency Response 50Hz - 8kHz
THD 0,5%
S/N ratio 75dB
Input Impedance 50k ohms
Power Consumption 80VA (max.)
Maximum Input Level 5Vrms
Dimensions (HxWxD) 445mm x 425mm x 300mm
Weight 12kg
1. Input 1: This is an instrument input for plugging in
virtually anything. You may plug in a guitar
(bass or lead), keyboard, CD-Player or any
pre-amplified signal.
2. Input 2: Second instrument input. Same instructions
apply as for input 1.
3. Volume 1: This is the overall level control to input 1
4. Volume 2: This is the overall level control to input 2
5. Low: EQ control for low frequency range (100Hz)
6. Middle 1: EQ control for mid frequency range (600Hz)
7. Middle 2: EQ control for mid frequency range (2kHz)
8. High: EQ control for high frequency range (6kHz)
9. Ext. Speaker: This jack is for plugging in an external
speaker. The internal speaker will be
disconnected automatically.
10. Headphones:Inserting a headphone jack will disconnect
internal speaker for quiet private practicing.
11. Line Output: Line signal output, Impedance = 1k ohms
12. Power: Power switch