User Manual
HI HLPRC03 SERIES LOAD POINT ASSEMBLY
Page 12
Specifications Operating Specifications
• Rated Output (F.S.)2+-0.002mv/v
• Non-Linearity+-0.012% R.O.
• Hysteresis<+-0.025% R.O.
• Zero Balance<+-1.0% R.O.
• Creep @ 5 Min.<+-0.010% R.O.
• Temp Effect Output<+-0.0014% R.O./C (.0011
on RCHO3)
• Temp Effect Sensitivity<+-0.0010% R.O./C
(.0005 on RCHO3)
• Input Resistance1050 to 1200 ohms +/- 50
• Output Resistance1000 +- 1 ohm +/- 10
• Insulation Resistance >5000 megohms
• Excitation 5-15VDC
• Safe Load Limit 200% Emax
• Ultimate Load 300% Emax
• Safe Side Load 100% Emax
Environmental Specifications
• Operating TemperatureMinus 40
o
F to Plus176
o
F (-40
o
C to +80
o
C)
• Compensated Temperature14
o
F to 104
o
F
(Minus 10
o
C to Plus 40
o
C)
Capacity Model # Model #
LBS MT Fixed Assembly Spare Load Sensor
66K 30 HI LPRC03-66K-45C HI RCH03-66K
110K 50 HI LPRC03-110K-45C HI RCH03-110K
200K 90 HI LPRBc03-200K-45C HI RCH03-200K
TABLE 1: MODEL NUMBERS & CAPACITIES