Product manual
Page 9For technical questions, please call 1-800-444-3353.SKU 37025
Quick
Coupler
Dryer
Recommended Air Line Components
Regulator with
Pressure Gauge
Quick
Coupler
Air Hose
on Reel
Valve Filter
Coupler
Plug
Tool
Air
Compressor
Coupler
Plug
Incorporate a lter, regulator with 1.
pressure gauge, dryer, in-line shutoff
valve, and quick coupler for best
service, as shown in the diagram
above. An in-line shutoff ball
valve is an important safety device
because it controls the air supply
even if the air hose is ruptured.
The shutoff valve should be a ball
valve because it can be closed
quickly.
Note: An oiler system should not be used
with this tool. The oil will mix with
the material being propelled, causing
poor gun plugging.
Attach an air hose to the 2.
compressor’s air outlet. Connect
air hose to the air inlet of the tool.
Other components, such as a coupler
plug and quick coupler, will make
operation more efcient, but are not
required.
WARNING! TO PREVENT SERIOUS
INJURY FROM ACCIDENTAL
OPERATION:
Do not install a female quick
coupler on the tool. Such a coupler
contains an air valve that will allow
the air tool to retain pressure and
operate accidentally after the air
supply is disconnected.
Note: Air ow, and therefore tool
performance, can be hindered by
undersized air supply components.
The air hose must be long enough 3.
to reach the work area with enough
extra length to allow free movement
while working.
Release the Trigger to turn the tool 4.
off.
Close the in-line safety valve between 5.
the compressor and the tool.
Turn on the air compressor according 6.
to the manufacturer’s directions and
allow it to build up pressure until it
cycles off.
Adjust the air compressor’s output 7.
regulator so that the air output is
enough to properly power the tool,
but the output will not exceed the
tool’s maximum air pressure of 120
PSI at any time. Adjust the pressure
gradually, while checking the air
output gauge to set the right pressure
range.
Inspect the air connections for leaks. 8.
Repair any leaks found.
If the tool will not be used at this time, 9.
turn off the compressor and detach
the air supply, safely discharge any
residual air pressure, and release
the throttle and/or turn the switch to
its off position to prevent accidental
operation.