Product manual

Page 9For technical questions, please call 1-800-444-3353.ITEM 60491
User-Maintenance Instructions
Procedures not specically explained
in this manual must be performed
only by a qualied technician.
TO PREVENT SERIOUS INJURY FROM
ACCIDENTAL OPERATION:
Detach the air supply and safely discharge any
residual air pressure in the tool before performing
any inspection, maintenance, or cleaning procedures.
TO PREVENT SERIOUS INJURY
FROM TOOL FAILURE:
Do not use damaged equipment.
If abnormal noise, vibration, or leaking air occurs,
have the problem corrected before further use.
Cleaning, Maintenance,
and Lubrication
Note: These procedures are in addition to the
regular checks and maintenance explained as part
of the regular operation of the air-operated tool.
1. BEFORE EACH USE, inspect the general condition
of the tool. Check for loose screws, misalignment or
binding of moving parts, clogged Ceramic Nozzle,
damaged supply hose, cracked or broken parts,
and any other condition that may affect its safe
operation. Do not use damaged equipment.
2. AFTER USE, clean external surfaces of tool with a
clean, moist cloth. If necessary, use a mild detergent.
WARNING! Do not use solvents or
immerse in liquids, as damage to the
Dead Man Valve may occur.
3. Store in a dry, secure area out of reach of children.
Troubleshooting
Problem Possible Causes Likely Solutions
Tool will not start. 1. Compressor not on.
2. Air line not connected properly.
1. Turn compressor on.
2. Check that air line is connected.
Blast ow surges /
Excessive abrasive consumption.
Air pressure too low. Increase air pressure.
Clogging and plugging
of blast ow.
Excessive debris in abrasive. Purge and lter abrasive.
Lack of abrasive ow. 1. Bag empty.
2. Moisture in abrasive
3. Not enough air pressure.
4. Air hose kinked.
5. Excessive debris in abrasive.
1. Fill Bag
2. Use dry abrasive.
3. Increase air pressure.
4. Un-kink air hose.
5. Clean or lter abrasive.
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect air supply before service.