Quick Start Guide
2
To suction
LP port
3
To discharge
HP port
3
CCW
4
CCW
4
3
Attach Couplers to
A/C system,
Blue to
suction LP port
and Red to
discharge HP port.
4
Turn on recovery system / vacuum pump.
Open Coupler Valves - turn CW.
Open Manifold Valves - turn CCW.
Read amount of vacuum on Blue LP Gauge.
5
Shut off recovery
system / vacuum
pump when vacuum
reaches manufacturer’s
recommendation.
Close Coupler Valves by
turning CCW.
Disconnect Couplers from
A/C system.
CW
4
CW
1
CW
4
CW
1
CCW
1
CCW
1
To refrigerant
recovery system
/ vacuum pump
2
Connect Red and Blue Hoses to Manifold
and Couplers as shown,
RED – RED and BLUE – BLUE.
Connect Yellow Hose to
refrigerant recovery system / vacuum pump.
2
2
Recovery / Evacuation
WARNING
A/C service can be dangerous.
To prevent SERIOUS INJURY,
read entire manual before use.
CONNECT HOSES:
ATTACH COUPLERS:
RECOVERY / EVACUATION:
AFTER:
1
CLOSE ALL VALVES:
Manifold Valves - turn CW.
Coupler Valves - turn CCW.