User Guide

SKU 94519 For technical questions please call 1-800-444-3353 Page 6
Attach the Adjustable Temperature Control Unit.
1. Mount the Adjustable Temperature Control
Unit to a secure location using the keyhole
hanger. The Control Unit must be mounted
inside the building for the temperature control
to function.
2. Attach the ring connectors from the Solar
Panels to the contacts on the Control Unit
marked “Solar. Attach the power cords to
the proper polarity. There should be two ring
connectors on each terminal.
Attach the Exhaust Fan.
Mount the Exhaust Fan in your building using
hardware (not supplied) in the holes drilled in
the edge of the fan. Be sure the fan is mounted securely, is protected from water
and other local materials which may damage it. A protective grid (not supplied)
must be installed on both sides of the fan to prevent injury.
CAUTION: The Fan may begin operating without notice whenever there is
sufficient electricity in the system from either the Solar Panels or the battery.
Attach an optional 12V battery.
1. It is recommended that a 12V 20 Ah battery (not included) be installed to store
spare electricity generated during the day so the fan can continue to operate
after daylight hours.
2. Battery Connector (jumper cables) are provided. Connect the RED cable to
the positive (+) connector of the Control Unit and the positive (+) pole of the
battery. Connect the BLACK cable to the negative (-) connector of the Control
Unit and the negative (-) pole of the battery.
CAUTION: The battery must be rated for 12V and at least 20 Amp-hours. A
lesser battery will be damaged if attached to this system.
CAUTION: If the fan is disconnected, also disconnect the battery. The battery
may be damaged if left connected to a solar panel system without the
fan operating.
Setting the Adjustable Temperature Control Unit.
1. Adjust the desired temperature by rotating the dial on the front to the desired
temperature. When the ambient temperature goes above the desired
temperature, the fan will go on, the fan will go off when the temperature falls
below the setting. The temperature range is 59° to 140° F (15° to 60° C).
2. The Control Unit has a built in regulator that will prevent battery discharge if
the battery level is less than 10.5 Volts or overcharge if the battery charge is
over 14.5 Volts.
Keyhole hanger