GAS ENGINE GENERATOR 13 HP Model 94191 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. CAUTION! Your Warranty Is Voided If: You do not put engine oil in the Engine’s crankcase prior to its first use. Before each use, check the oil level. Never run the Engine with low or no engine oil. Running the Engine with low or no oil will permanently damage the unit. ® 3491 Mission Oaks Blvd.
SPECIFICATIONS Electrical Specifications Alternator Type: 2-Pole, Single Phase Output Frequency: 60 Hz Output: 5,500 Continuous Watts / 6,500 Peak Watts AC Receptacles: Dual 120V, 20 Amp grounded receptacle 240V, 30 Amp, L14-30, four blade twist lock receptacle DC Receptacle: 12V Terminal with Cap Screws Circuit Breakers: 20 Amp, Qty. 2 / 25 Amp, Qty.
. Keep bystanders, children, and visitors away while operating a power tool. Distractions can cause you to lose control. Provide barriers or shields as needed. PERSONAL SAFETY 1. Stay alert. Watch what you are doing, and use common sense when operating a power tool. Do not use a power tool while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating power tools may result in serious personal injury. 2. Dress properly.
6. Use only accessories that are recommended by the manufacturer for your model. Accessories that may be suitable for one tool may become hazardous when used on another tool. SERVICE 1. Tool service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury. 2. When servicing a tool, use only identical replacement parts. Follow instructions in the “Inspection, Maintenance, And Cleaning” section of this manual.
9. Do not force the Generator. This tool will do the work better and safer at the speed and capacity for which it was designed. Do not overload the generator. Know the total running wattage necessary to power the desired items. FIRE AND EXPLOSION PRECAUTIONS 1. Gasoline fuel and fumes are flammable, and potentially explosive. Use proper fuel storage and handling procedures. Always have multiple ABC class fire extinguishers nearby. 2.
if fuel is swallowed. For skin contact, immediately wash with soap and water. For eye contact, immediately flush eyes with clean water. NOISE PRECAUTIONS Prolonged exposure to high noise levels is hazardous to hearing. Always wear ANSI approved hearing protection when operating or working around the Generator when it is running. ELECTRICAL PRECAUTIONS 1.
RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120 or 240 VOLT) NAMEPLATE AMPERES EXTENSION CORD LENGTH (at full load) 25 Feet 50 Feet 75 Feet 100 Feet 150 Feet 0 – 2.0 18 18 18 18 16 2.1 – 3.4 18 18 18 16 14 3.5 – 5.0 18 18 16 14 12 5.1 – 7.0 18 16 14 12 12 7.1 – 12.0 18 14 12 10 - 12.1 – 16.0 14 12 10 - - 16.1 – 20.0 12 10 - - - TABLE A * Based on limiting the line voltage drop to five volts at 150% of the rated amperes. MISC. PRECAUTIONS 1.
UNPACKING When unpacking, check to make sure all the parts shown on the Parts Lists on pages 20 and 22 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible. ASSEMBLY INSTRUCTIONS CAUTION! Make sure Engine’s Ignition (2) is in its “OFF” position prior to performing any service, maintenance, or cleaning of Generator or Engine.
INSTALLATION INSTRUCTIONS 1. Electrical and other permits may be required for the installation of emergency or portable power systems. Investigate the local building and electrical codes before installing this unit. 2. Prior to providing Generator power to tools and equipment, make sure the Generator’s rated voltage, wattage, and amperage capacity is adequate to supply all electrical loads the unit will power.
Grounding The Generator: GROUNDING TERMINAL (9) #6 AWG GROUNDING WIRE (NOT INCLUDED) GROUNDING ROD (NOT INCLUDED) FIGURE C Note: It is recommended that only a trained and licensed electrician perform this procedure. Connect a #6 AWG grounding wire (not included) from the Grounding Terminal (9) on the Generator to a grounding rod (not included) that has been driven at least 24 inches deep into the earth.
(65) (2) (3) (34) (8) (5) (6) (10) (7) FIGURE D 4. 120 Volt AC Circuit Breakers (3): Each of the two 120 Volt AC Outlets have a Circuit Breaker to protect the Generator from overloading. Should a Circuit Breaker “trip”, unplug all electrical loads from the Generator. Allow the Circuit Breaker to cool down. Then, push the 120 volt Circuit Breakers. (See Figure D.) 5.
8. 12 Volt DC Fuse (8): The 12 Volt DC Outlet has one Fuse (8) to protect the Generator from overloading. The Generator is equipped with the following size and type of Fuse: F10A250V. Should a 12 VDC output exceed the fuse’s rating, always check to see if the Fuse has “blown” (a melted filament within the Fuse). If necessary, unplug all electrical loads from the Generator, replace with a new Fuse, and reattach a reduced load to the generator. (See Figure D.) 9.
Engine will be run in temperatures below 32 degrees Fahrenheit, use SAE 5W-30 weight oil. (See Figure E, prior page.) 3. To do so, unscrew and remove the Oil Dipstick (65A). Pour engine oil into the Dipstick Hole until the level of oil is even with top edge of the Dipstick Hole. (See Figure E.) 4. Make sure to screw the Oil Dipstick (65A) firmly back into its Dipstick Hole. (See Figure E.) To Fill The Fuel Tank: 1.
To Start The Engine/Generator: ON OFF FUEL VALVE (41) CHOKE LEVER (21A) CHOKE LEVER (21A) (IN “CHOKE” POSITION) (IN “RUN” POSITION) FIGURE F 1. Turn the Engine Fuel Valve (41) to its “OPEN” position. Then, turn the Engine Choke Lever (21A) to its “CHOKE” position. NOTE: No choke is required if the Engine is warm. Make sure the Engine Choke Lever is in the “RUN” position when starting a warm Engine. (See Figure F.) 2.
to the one 240V AC Outlet (6). Connect 12V DC appliances, tools, and equipment only to the 12V DC Terminal (7). (See Figure D.) 3. CAUTION! Never exceed the rated capacity for this Generator, as serious damage to the Generator and/or appliances, tools, and equipment could result from an overload. Starting and running wattage requirements should always be calculated when matching this Generator’s wattage capacity to the appliance, tool, or equipment. 4.
11. When finished using the Generator, disconnect all electrical loads. Turn the Engine Ignition (2) to its “OFF” position to stop the Engine. Then, close the Engine Fuel Valve (41). (See Figures D and F.) INSPECTION, MAINTENANCE, AND CLEANING 1. WARNING! Always make sure the Engine’s Ignition (2) is in its “OFF” position prior to performing any service, maintenance, or cleaning of the Generator or Engine. (See Figure D.) 2. Before each use, inspect the general condition of the Generator and Engine.
PLUG (59A) OIL DIPSTICK (65A) FIGURE G 4. Engine maintenance: a. After first 5 to 8 hours of use: Change oil. Then, change oil every 50 hours of use. Change oil every 25 hours of use when operating the Engine under a heavy load or in high temperatures. To change the oil, remove the Plug (59A) and allow the old oil to drain in a proper container. Once drained, replace the Plug. If the Engine will be run in temperatures above 32° Fahrenheit, use SAE 30 weight oil.
squeeze thoroughly to dry. Then, squirt several drops of a light weight oil onto the Element. Use compressed air to clean the Air Filter Separator. Then replace the Air Filter Separator, Air Filter Element, and Air Filter Cover. Clean more often under dusty conditions or when airborne debris is present. Replace Air Filter parts if necessary. (See Figure H.) c. After every 100 hours of use: Replace the Spark Plug (28A). To do so, remove the Spark Plug Wire (36A).
TROUBLESHOOTING PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT.
PARTS LIST - GENERATOR SKU 94191 For technical questions, please call 1-800-444-3353.
ASSEMBLY DIAGRAM - GENERATOR SKU 94191 For technical questions, please call 1-800-444-3353.
PARTS LIST - ENGINE Part 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 13A 14A 15A 16A 17A 18A 19A 20A 21A 22A 23A 24A 25A 26A 27A 28A 29A 30A 31A 32A 33A 34A 35A 36A 37A 38A 39A 40A 41A 42A 43A Description Muffler Cylinder Head Bolt Cylinder Head Cover Bolt Cylinder Head Cover Lock Nut Adjusting Screw Rocker Arm Rocker Arm Bolt Valve Push Rod Guiding Board Valve Push Rod Cylinder Head Carburetor Shield Carburetor Packing Carburetor Assembly Air Filter Case Air Filter Seal Bolt (M6) Air Filter Cover Air Filter El
SKU 94191 4A 3A 2A 1A 5A 33A 6A 7A 32A 31A 78A 79A 80A 77A 8A 9A 12A For technical questions, please call 1-800-444-3353. 15A 14A 16A 24A 23A 22A 21A 25A 56A 74A 75A 35A 57A 34A 13A 26A 27A 28A 10A 11A 29A 30A 82A 81A 76A 17A 85A 83A 20A 38A 50A 59A 58A 19A 52A 84A 51A 54A 53A 36A 37A 55A 18A 48A 62A 39A 40A 46A 41A 68A 45A 70A 69A 65A 66A 67A 71A 64A 47A 63A 72A 43A 44A 42A 86A: Spark Plug Wrench Kit Not Shown.
Limited 1 year warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of one year from the date of purchase (90 days if used by a professional contractor or if used as rental equipment). See engine manufacturer’s warranty which covers engine.
Emission Control System Warranty - continued Harbor Freight Tools Emission Control Defects Warranty Provisions 1. Length of Coverage HFT warrants to a first retail purchaser and each subsequent purchaser that the engine is free from defects in materials and workmanship that cause the failure of warranted parts for a period of two (2) years after the date of delivery to the first retail purchaser. 2. 5.
Electrical Diagram Please note: All electrical work should be performed by a qualified service technician. SKU 94191 REV 07c, 07h For technical questions, please call 1-800-444-3353.