WALLPAPER STEAMER Model 91098 ASSEMBLY AND OPERATING INSTRUCTIONS ® 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com Copyright© 2004 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. For technical questions, please call 1-800-444-3353.
PRODUCT SPECIFICATIONS Motor 120V, 1200 Watts Tank Capacity 1.2 Gallons Steam Duration 140 Minutes Working Temperature 212° Fahrenheit Rise Time To Steam 5 to 25 Minutes Steam Plate 7” W x 11” L Power Cord 16 AWG x 6 Feet Features a Thermal Safety Cut-off Switch. E224797 SAVE THIS MANUAL You will need this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures, parts list and assembly diagram. Keep your invoice with this manual.
ELECTRICAL SAFETY 4. Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any adapter plugs. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. If the tools should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user. 5.
TOOL USE AND CARE 14. Do not force the tool. Use the correct tool for your application. The correct tool will do the job better and safer at the rate for which it is designed. 15. Disconnect the Power Cord Plug from the power source and allow the unit to cool before making any adjustments, changing accessories, or storing the tool. 16. Store idle tools out of reach of children and other untrained persons. Tools are dangerous in the hands of untrained users. 17. Maintain tools with care.
4. Avoid unintentional starting. Make sure you are prepared to begin work before plugging in the Steamer. 5. Do not force the Steamer. This tool will do the work better and safer at the speed and capacity for which it was designed. 6. Never leave the Steamer unattended when it is plugged into an electrical outlet. Unplug it from its electrical outlet and allow it to cool before leaving. 7.
GROUNDING WARNING! Improperly connecting the grounding wire can result in the risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use.
DOUBLE INSULATED TOOLS: TOOLS WITH TWO PRONG PLUGS 4. Tools marked “Double Insulated” do not require grounding. They have a special double insulation system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association, and the National Electrical Code. (See Figure B.) 5. Double insulated tools may be used in either of the 120 volt outlets shown in the following illustration. (See Figure B.) FIGURE B EXTENSION CORDS 1.
6. If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use. 7. Make sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it. 8. Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.
UNPACKING When unpacking, check to make sure all the parts shown on the Parts List on page 12 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible. ASSEMBLY AND OPERATING INSTRUCTIONS NOTE: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram on page 12.
OPERATING INSTRUCTIONS Wallpaper Stripping FIGURE 3 Note: FIGURE 3 shows the Steam Plate (6) connected to the Hose (4), which is connected to the Boiler Unit (8). 1. After connecting the Steam Plate (6) accessory to the Boiler Unit (8), plug in the Power Cord (12) and wait approximately 25 minutes for the unit to produce steam. Warning!! Once the unit is heated, it is constantly produces steam that causes severe burns if it comes in contact with unprotected skin.
TROUBLESHOOTING The Boiler Unit (8) fails to produce steam. 1. Check that the Power Cord (12) is properly plugged into the wall outlet and the Boiler Unit (8). 2. If the safety cut-off engaged, it will need ample time to cool and reset. 3. The safety cut-off device was damaged from working with a tilted unit. The Boiler Unit (8) leaks steam from the pressure release valve. 1. The pressure release valve is a special low pressure valve that cannot be replaced by another valve.
ASSEMBLY DIAGRAM 2 3 1 9 4 9 12 5 6 8 10 7 11 NOTE: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. PARTS LIST Part No. 1 2 3 4 5 6 Description Brush Brush Handle Connector Hose Filler Cap Steam Plate Part No.