Product manual

Page 10 For technical questions, please call 1-800-444-3353. Item 61615
SAFETY OPERATION MAINTENANCESETUP
Operating Instructions
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
Compressor Area Set Up
1. Designate a work area that is clean and well-lit.
The work area must not allow access by
children or pets to prevent injury.
2. Locate the Compressor on a flat level surface to
ensure proper pump lubrication and to prevent
damage to the unit. Keep at least 12″ of space
around the unit to allow air circulation.
3. Route the power cord from the compressor
to the grounded wall outlet, along a safe path
without creating a tripping hazard or exposing
the power cord to possible damage.
General Operation
1. Turn red regulator knob
counterclockwise completely.
2. Close the Drain Valve.
3. Plug the Air Compressor Power Cord into
a grounded 120 V~ electrical outlet.
Off On Reset
4. Turn the Switch ON (the | position)
and press the black Reset button
next to the Switch.
5. Allow the Air Compressor to build
up pressure until it cycles off.
Note: At the beginning of the day’s first use
of the Air Compressor, check for air leaks by
applying soapy water to connections while the
Air Compressor is pumping and after pressure cut-out.
Look for air bubbles. If air bubbles are present at
connections, tighten connections. Do not use the
Air Compressor unless all connections are air tight,
the extra air leaking out will cause the compressor to
operate too often, increasing wear on the compressor.
Note: As long as the Power Switch is ON, the operation
of the Air Compressor is automatic, controlled by an
internal pressure switch. The Compressor will turn on
automatically when the air pressure drops to 85 PSI,
and will turn off automatically when the
air pressure reaches 100 PSI.
WARNING! TO PREVENT SERIOUS
INJURY AND DEATH FROM
EXPLOSION:
Do not adjust the internal
pressure switch. Any change to the
automatic pressure levels may cause excess pressure to
accumulate, causing a hazardous situation.