Product manual
Page6 For technical questions, please call 1-800-444-3353. Item61176
SAFETY OPERATION MAINTENANCESETUP
7. Makesuretheextensioncordisproperly
wiredandingoodelectricalcondition.
Alwaysreplaceadamagedextension
cordorhaveitrepairedbyaqualified
electricianbeforeusingit.
8. Protecttheextensioncordsfrom
sharpobjects,excessiveheat,
anddamporwetareas.
Table A: Recommended Minimum
Wire Gauge for Extension Cords*
(120/240 Volt)
NAMEPLATE
AMPERES
(at full load)
EXTENSION CORD
LENGTH
25´
50´
75´
100´
150´
0–2.0 18 18 18 18 16
2.1–3.4 18 18 18 16 14
3.5–5.0 18 18 16 14 12
5.1–7.0 18 16 14 12 12
7.1–12.0 18 14 12 10 -
12.1–16.0 14 12 10 - -
16.1–20.0 12 10 - - -
* Based on limiting the line voltage drop to
five volts at 150% of the rated amperes.
Symbology
DoubleInsulated
CanadianStandardsAssociation
UnderwritersLaboratories,Inc.
V
Volts
~
AlternatingCurrent
A
Amperes
n
0
xxxx/min.
NoLoadRevolutions
perMinute(RPM)
WARNINGmarkingconcerning
RiskofEyeInjury.
WearANSI-approvedsafety
goggleswithsideshields.
Readthemanualbefore
set-upand/oruse.
WARNINGmarkingconcerning
RiskofFire.
Donotcoverventilationducts.
Keepflammableobjectsaway.
WARNINGmarkingconcerning
RiskofElectricShock.
Properlyconnectpower
cordtoappropriateoutlet.
Specifications
ElectricalRating 120V~/60Hz/5A
AirDisplacement 3CFM
Fittings R134AandR12/R22
UltimateVacuum 22.5micron(3Pascal)
OilCapacity 6.8Ounces(200ml)
WorkingPressure 15PSI
231672
VE225