Product manual
Page5For technical questions, please call 1-800-444-3353.Item61176
SAFETYOPERATIONMAINTENANCE SETUP
Grounding
TO PREVENT ELECTRIC SHOCK AND DEATH
FROM INCORRECT GROUNDING WIRE CONNECTION:
Check with a qualified electrician if you are in doubt as to whether the outlet is
properly grounded. Do not modify the power cord plug provided with the tool.
Never remove the grounding prong from the plug. Do not use the tool if the power cord or
plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will
not fit the outlet, have a proper outlet installed by a qualified electrician.
Grounded Tools: Tools with Three Prong Plugs
3-Prong Plug and Outlet
1. Toolsmarkedwith“GroundingRequired”
haveathreewirecordandthreeprong
groundingplug.Theplugmustbeconnected
toaproperlygroundedoutlet.Ifthetool
shouldelectricallymalfunctionorbreak
down,groundingprovidesalowresistance
pathtocarryelectricityawayfromtheuser,
reducingtheriskofelectricshock.
2. Thegroundingprongintheplugis
connectedthroughthegreenwireinside
thecordtothegroundingsysteminthetool.
Thegreenwireinthecordmustbe
theonlywireconnectedtothetool’s
groundingsystemandmustneverbe
attachedtoanelectrically“live”terminal.
3. Thetoolmustbepluggedintoanappropriate
outlet,properlyinstalledandgroundedin
accordancewithallcodesandordinances.
Theplugandoutletshouldlooklikethosein
theprecedingillustration.
(See 3-Prong Plug and Outlet.)
Extension Cords
1. Groundedtoolsrequirea
threewireextensioncord.
Double Insulatedtoolscanuseeither
atwoorthreewireextensioncord.
2. Asthedistancefromthesupplyoutlet
increases,youmustuseaheaviergauge
extensioncord.Usingextensioncordswith
inadequatelysizedwirecausesaserious
dropinvoltage,resultinginlossofpower
andpossibletooldamage.(See Table A.)
3. Thesmallerthegaugenumberofthewire,
thegreaterthecapacityofthecord.For
example,a14gaugecordcancarryahigher
currentthana16gaugecord.(See Table A.)
4. Whenusingmorethanoneextensioncord
tomakeupthetotallength,makesure
eachcordcontainsatleasttheminimum
wiresizerequired.(See Table A.)
5. Ifyouareusingoneextensioncordformore
thanonetool,addthenameplate amperes
andusethesumtodeterminetherequired
minimumcordsize.(See Table A.)
6. Ifyouareusinganextensioncord
outdoors,makesureitismarkedwiththe
suffix“W-A”(“W”inCanada)toindicate
itisacceptableforoutdooruse.