Before start-up, note the following: CAUTION Item 69296: This pump is intended for use with clear water only. The pump can be connected to any shockproof plug which has been installed according to regulations. The plug must have a supply voltage of 110-120 V~ at 60 Hz. Items 69298, 69299, 69300, 69301: These pumps are intended for use with clear or dirty water only. WARNING IMPORTANT! Before starting to run Pump, please have the following items checked by an expert: 1.
Installation The submersible pump must be installed with either: a. A fixed pipeline or b. A flexible hose pipe. Please note! 1. Do not install the pump by suspending it unsupported from its delivery pipe or power cord. The pump must be suspended from the handle or be placed on the bottom of the area. 2. Make sure the Pump rests on flat, level and solid foundation. Do not operate it on earth, clay, sand or gravel surfaces. 3. Make sure the Pump’s inlet openings near the Base are free of debris. 4.
Operation 1. After reading these instructions, consider the following points before starting the pump: a. Verify that the pump rests on the floor of the shaft, if it is not suspended by the handle. b. Verify that the delivery pipe is properly connected. c. Verify that the electrical connection is 110-120 V~, 60 Hz. d. Verify that the electrical socket is in good condition. e. Verify that water and moisture cannot get near the power supply socket or power cord connection. 2.
Maintenance TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: Unplug the Pump from its electrical outlet before performing any inspection, maintenance, or cleaning procedures. If the pump is moved during operation, flush it out with clean water after every use. Quarterly Maintenance The below maintenance must be performed at least once every 3 months under optimal conditions. For frequent use, or dirty areas, more frequent maintenance is required. 1. Clean sludge and debris from the Base of the Pump.
Troubleshooting Problem Possible Causes Possible Solutions Pump runs, but will not deliver any water. 1. Impeller clogged. 2. When starting, the water height falls below the minimum water level. 3. Low line voltage. 4. Check valve (if installed) stuck or installed backwards. 1. Clean out dirt and debris from impeller. 2. Water must be deep enough for the Pump to operate properly. 3. Consult with an electrician. 4. Remove and examine check valve. Pump won’t start or run. 1.
Parts Lists and Diagrams Record Product’s Serial Number Here: Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. Note: If product has no serial number, record month and year of purchase instead. 69296 Parts List and Diagram Part 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Description Cross Head Screw ST4.2×16 Plain Washer 4 Base Plate Cross Head Screw ST4.2×22 Base O-ring 148.8×3.1 Plain Washer 4 “Y” - Screw YST4.
69298 Parts List and Diagram Part 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Page 8 Description Cross Head Screw ST4.2×16 Plain Washer 4 Base Plate Cross Head Screw ST4.2×22 Base O-ring 148.8×3.1 Plain Washer 4 “Y” - Screw YST4.7×35 Pump Body O-ring 34.8×3.1 Junction Flange Nut M8 Impeller Mechanical Seal 301-12 O-ring 90×4.
69299 Parts List and Diagram Part 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Description Cross Head Screw ST4.2×16 Plain Washer 4 Base Plate Pump Body O-ring 34.8×3.1 Junction Junction Gasket Supporter Gasket Supporter “Y” - Screw YST4.7×35 Plain Washer Supporter Flange Nut M8 Impeller Mechanical Seal 301-12 O-ring 90×4.
69300 Parts List and Diagram Part 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Description Pump Body O-ring 42.5×2.65 Junction Junction Gasket Supporter “Y” - Screw YST4.7×30 Washer Supporter Flange Nut M8 Impeller Mechanical Seal 301-12 O-ring 90×4.
69301 Parts List and Diagram Part 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Description Cross Head Screw ST4.2×16 Plain Washer 4 Base Plate Cross Head Screw ST4.2×22 Base O-ring 150×2.65 Supporter O-ring 148.8×3.1 Plain Washer 4 “Y” - Screw YST4.7×35 Pump Body O-ring 34.8×3.1 Junction Flange Nut M8 Impeller Mechanical Seal 301-12 O-ring 90×4.
Limited 90 Day Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase.