Product manual

Page 13For technical questions, please call 1-888-866-5797.Item 61932
NOTICE
FOR CEMENT AND MORTAR ONLY.
Do not use with Epoxy 2-part resin mix.
SAFETYOPERATIONMAINTENANCE SETUP
Troubleshooting
Problem Possible Causes Likely Solutions
Tool will not start. 1. Cord not connected.
2. No power at outlet.
3. Internal damage or wear.
1. Check that cord is plugged in.
2. Check power at outlet. If outlet is unpowered, turn
off tool and check circuit breaker. If breaker is
tripped, make sure circuit has the correct capacity
for the tool and circuit has no other loads.
3. Have technician service tool.
Tool operates slowly. Extension cord too long or
wire size too small.
Eliminate use of extension cord. If an extension
cord is needed, use shorter/heavier gauge cord.
See Extension Cords in GROUNDING section.
Excessive noise
or rattling.
1. Belt too loose (slipping) or
too tight (bearing damage).
2. Internal damage or wear.
1. Properly tension belt.
2. Have technician service tool.
Overheating/
Overloading.
1. Running at 100% load
for extended time.
2. Blocked motor housing vents.
3. Motor being strained by long or
small diameter extension cord.
1. Allow for lighter no-load intervals.
2. Wear ANSI-approved safety goggles and NIOSH-
approved dust mask/respirator while blowing
dust out of motor using compressed air.
3. Eliminate use of extension cord. If an
extension cord is needed, use one with the
proper diameter for its length and load. See
Extension Cords in GROUNDING section.
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect power supply before service.