Product manual
Page 8 For technical questions, please call 1-888-866-5797. ITEM 62204
SAFETY OPERATION MAINTENANCESETUP
Operation
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual
including all text under subheadings therein before set up or use of this product.
Controls and Indicators
1
2
3
4
5
6
7
8
POWER
ON
POWER CUTTING
CURRENT
MIN MAX
SET AIR
CUT
OVER
LOAD
OFF
ITEM 62204
0
30
60
90
120PSI
Figure C
1� Output Current Knob
Turn the Output Current Knob to the desired
current (15 to 40 amps)� Lower currents reduce
circuit breaker tripping� Adjust as needed after
test cuts�
Thicker material will use greater amperage�
Thinner material will use lower amperage�
2� Air Pressure Gauge
3� Digital Amp Meter
Shows actual cutting current,
which will vary during operation�
4� Power ON Light
Green light will be on when power is on�
5� Thermal Overload Light
Yellow light will be on if the Plasma Cutter
shuts down due to overload� Stop using the
Plasma Cutter while leaving the Power Switch ON
to allow the cooling fan to operate�
The light will turn off automatically when the
Plasma Cutter cools down.
Continue use while paying attention to
Duty Cycle discussed on page 10.
6� Cutting Light
Red light will be on during cutting operation�
7� Air Switch
CUT: For cutting operation.
SET AIR: Produces constant air flow for
SETTING AIR PRESSURE ONLY�
Not for cutting operation.
8� Power Switch & Circuit Breaker
Up is ON, down is OFF�
This switch also functions as a circuit breaker�
It will trip (disconnect power) if overcurrent occurs�
Turn OFF, then back to ON to reset it�