Product manual

Page 14 For technical questions, please call 1-888-866-5797. ITEM 62204
SAFETY OPERATION MAINTENANCESETUP
Troubleshooting (cont.)
Air pressure too high or too low.
Check the air pressure setting on
both the Compressor and the Cutter.
Set Compressor's Air
Pressure Regulator
between 90 - 120 PSI.
AIR PRESSURE
TOO HIGH
AIR PRESSURE
TOO LOW
a. Verify that the compressor is
delivering 4.5 CFM @ 80 PSI.
b. Set Cutter's Air
Pressure Regulator
between 60 - 80 PSI.
c. Verify air flow by
performing "Test Air
Flow:" on page 7.
Use a wire wheel brush or sander
(not included) to thoroughly
clean both the grounding point
and the area that will be cut.
If any cleaners are used, allow them
to dry thoroughly before continuing.
DIRTY OR
COATED METAL
METAL IS CLEAN IN
BOTH AREAS
Torch isn’t maintaining contact with the workpiece.
a. Maintain a 1/16" distance
from workpiece at all times.
b. Disassemble Torch, inspect and replace worn
components, then reassemble Torch tightly
according to number 2 on page 10.
c. Torch is moving too slowly across the metal
and cutting the material from underneath,
breaking contact. Move Torch more quickly.
AIR PRESSURE
CORRECT
IMPORTANT!
Be CERTAIN to shut off the Plasma Cutter, and disconnect it from power and air before adjusting, cleaning,
or repairing the unit. A technician should discharge all capacitors before performing any internal procedures.
If the steps above do not solve the problem or if the repairs involved are too
complex, contact a qualified technician.
ARC IGNITES FOR SEVERAL SECONDS BUT THEN GOES OUT
Check that the grounding point and the
metal being cut are both clean, dry, and
free from paint, oil, or dirt.
These sections need to conduct
electricity efficiently.