Product manual

Page 8 For technical questions, please call 1-888-866-5797. ITEM 69774
SAFETY SETUP OPERATION MAINTENANCE
Connecting Hoses
Note: Hose coupling components
and hoses not included.
Note: The Suction Hose (not included) MUST
be reinforced with braided material or have
non-collapsible construction. Do not use a
hose with an inside diameter smaller than 2″
(pump’s intake and discharge port diameters).
CAUTION: Do not over-tighten Hose Clamps as the
clamp may damage the hose or other components.
1. Slide one of the Hose Coupling Rings over
one of the Hose Couplers (a), then place a
Gasket on the end of the Hose Coupler (b).
Gasket
Hose Coupler
Hose Coupling Ring
a
b
2. Thread the Hose Coupling Ring onto the Intake Port
(a), and turn clockwise until fastened securely (b).
Intake Port
3. Slide one of the Hose Clamps over the end of the
suction hose (a). Slide the Hose onto the Hose
Coupler (b). Use a screwdriver (not included)
to tighten the Hose Clamp until secure.
CAUTION: Use only a non-collapsible intake hose.
a
b
Hose Clamp
Suction Hose
4. Slide a Hose Clamp over the other end of the
suction hose (a). Slide the Intake Strainer into the
end of the suction hose (b). Use a screwdriver
to tighten the Hose Clamp until secure.
Intake Strainer
a
b
5. For the discharge hose, slide a Hose Coupling Ring
over the remaining Hose Coupler (a) and place
a Gasket onto the end of the Hose Coupler (b).
a
b