Product manual

Page 13For technical questions, please call 1-800-444-3353.61619
SAFETYOPERATIONMAINTENANCE SETUP
Loading the Tool
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION, BEFORE LOADING:
•Wear ANSI-approved safety goggles with side shields.
Other people in the work area must also wear ANSI-approved impact safety goggles with side shields.
•Release the trigger.
•Detach the air supply.
•Attempt to fire the Tool into a piece of scrap wood to ensure that it
is disconnected and is incapable of firing any fasteners.
1. Only use the proper size and type
of staple with this tool.
2. Press down on the Magazine Release to open
the Magazine. Open the Magazine completely.
3. Turn the Stapler upside down. Place a full clip of
staples inside the Magazine so the pointed ends
of the staples are directed away from the tool.
4. Keep fingers clear while sliding the
Magazine closed until it clicks shut.
General Operating Instructions
1. Before each use, test the tool as
directed in the prior section.
2. If an automatic oiler is not used, add a few
drops of Pneumatic Tool Oil to the airline
connection before use. Add a few drops
more after each hour of continual use.
WARNING! TO PREVENT
SERIOUS INJURY: Keep second hand
away from tool discharge area,
especially if holding workpiece.
Tool applies extreme force to fastener,
and fasteners may deflect or fire in an
unexpected direction.
CAUTION! TO PREVENT INJURY: Do not hold tool
near body while firing. Tool recoil can cause injury.
3. Rotate the Air Deflector to redirect
exhaust air away from you.
4. Position tool at the desired fastener
location and depress the Safety Nosepiece
fully against the workpiece.
5. Squeeze the Trigger to fire a fastener.
6. If the tool requires more force to accomplish
the task, verify that the tool receives sufficient,
unobstructed airflow (CFM) and increase the
pressure (PSI) output of the regulator up to the
maximum air pressure rating of this tool.
CAUTION! TO PREVENT INJURY FROM TOOL
OR ACCESSORY FAILURE:
Do not exceed the tool’s
maximum air pressure rating of 110 PSI.
If the tool still does not have sufficient force
at maximum pressure and sufficient airflow,
then a larger tool may be required.
7. After use, to prevent accidents:
a. Release the Trigger.
b. Detach the air supply.
c. Attempt to fire the tool into a piece of scrap
wood to ensure that it is disconnected
and is incapable of firing any fasteners.
d. Release the Trigger again.
e. Clean external surfaces with clean, dry cloth.
f. Store indoors out of children’s reach.