Product manual

Page 9For technical questions, please call 1-800-444-3353.Item 61483
SAFETYOPERATIONMAINTENANCE SETUP
Operating Instructions
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
Tool Set Up
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Turn the Power Switch of the tool off and unplug the tool from its electrical
outlet before performing any procedure in this section.
TO PREVENT SERIOUS INJURY: DO NOT OPERATE WITH ANY GUARD DISABLED,
DAMAGED, OR REMOVED. Moving guards must move freely and close instantly.
Table Adjustment
The Table is capable of moving in
four directions. See Figure B.
1. Raise or lower the Table by loosening the
Arm Locking Handle (A) and turning the
Table Crank (C): clockwise to raise the Table
and counterclockwise to lower the Table.
2. Swivel the Table around the column by loosening
the Arm Locking Handle. The table assembly, arm
and rack (B), move as one around the column.
3. Tilt the table by loosening the Bolt (E), and tilting the
Table to the required angle.
A scale (F) is provided on the arm to assist
in setting the required angle. For all normal
operations the Table angle should be set at 0°.
IMPORTANT: TO ENSURE THAT THE DRILL
IS ENTIRELY PERPENDICULAR TO THE
TABLE: Insert a piece of straight round bar in
the Chuck, place a square on the Table and
raise the table to bring the square up to the
round bar. Adjust the Table tilt if necessary
so that the Table is correctly aligned.
4. Spin the Table about its axis by loosening
the Table Locking Handle (D).
Figure B: Table Adjustments
Setting Drilling Depth
See Figure C.
Located around the Spindle Feed Shaft is a
Depth Stop Collar (A) carrying a graduated scale.
The Collar will turn around the Shaft, and can
be locked in place by a Lock Knob (B).
1. With the power to the Drill Press switched OFF, use
the Spindle Feed Handles to lower the drill until the
bit contacts the workpiece and hold it in that position.
2. Loosen the Lock Knob and turn the Collar so
that the measurement for the required hole
depth is aligned with the Pointer (C).
3. Tighten the Lock Knob to lock
the Collar in this position.
Figure C: Drill Depth Adjustment