Product manual

Page 8 For technical questions, please call 1-888-866-5797. Item 32888
SAFETY OPERATION MAINTENANCESETUP
User-Maintenance Instructions
Procedures not specifically explained in this manual must
be performed only by a qualified technician.
TO PREVENT SERIOUS INJURY FROM TOOL FAILURE:
Do not use damaged equipment. If abnormal noise or vibration
occurs, have the problem corrected before further use.
1. BEFORE EACH USE, inspect the general condition
of the Pipe Bender and Ram. Check for:
• loose hardware,
• misalignment or binding of moving parts,
• cracked or broken parts,
• any condition that may affect its safe operation.
If a problem occurs, have the problem corrected
before further use.
Do not use damaged equipment.
2. BEFORE EACH USE, thoroughly test the Ram
for proper operation prior to its actual use.
If the Ram appears not to be working properly,
follow Bleeding instructions on page 5.
3. AT LEAST ONCE EVERY THREE YEARS,
change the hydraulic fluid:
a. Remove Ram from Pipe Bender
by removing two Bolts (5).
b. With the Ram fully lowered, remove the Fill Plug.
c. Tip the Ram over to allow the old
hydraulic fluid to drain out completely.
Dispose of the old hydraulic fluid in
accordance with local regulations.
d. With the Ram upright, completely fill the
Hydraulic Unit with high grade hydraulic fluid until
the fluid is 1/4″ below the top of the Fill Port.
e. Turn the Release Knob counterclockwise
to open the Release Valve.
f. Pump the Handle up and down quickly
several times to purge air from the system.
g. Recheck fluid level and re-fill as needed.
h. Replace the Fill Plug.
i. Replace Ram on Pipe Bender.
4. AFTER EACH USE, wipe with a clean cloth.
Store indoors out of children’s reach.