Cold Weather Operation
Start compressor in heated area if outdoor temperatures
drop below 32° F.
If this is not practical, drain out the old pump oil
and use SAE 10W Non-detergent Air Compressor
Oil in the pump crankcase instead whenever the
compressor’s temperature will fall below 40°.
• Do not use multi-viscosity oil (such as
10W-30) - they leave carbon deposits on pump
components and lead to accelerated failure.
• Heavy operation may require heavier viscosity oil.
Emergency Depressurization
If it is necessary to quickly depressurize the Compressor:
1. Move the ON/OFF Power Lever to the OFF position. 2. Pull on the ring on the Safety Valve (73)
to quickly release stored air pressure.
Automatic Shut off System
1. If the Compressor automatically shuts off
before reaching its normal cutoff pressure:
a. Shut off all tools.
b. Wait until the Compressor cools down
(about 10 minutes);
c. If the unit does not start up again on its own,
press the Reset Button to start the compressor;
Reset Button
d. Resume operation.
2. Possible causes of repeated automatic
shut off of the compressor are:
a. Using an extension cord that is too
long or too small a gauge;
b. An air leak or open hose causing the compressor
to cycle too often and build up heat.
Correct any issues before further use to
avoid damage to the compressor.