Product manual

Page 5For technical questions, please call 1-800-444-3353.Sewage Pump manual
Maintenance
TO PREVENT SERIOUS INJURY FROM
ACCIDENTAL OPERATION:
Unplug the Pump from its electrical outlet and
ALLOW TO COOL FOR AT LEAST 2 HOURS before
performing any inspection, maintenance, or
cleaning procedures.
TO PREVENT SERIOUS INJURY FROM ILLNESS:
Submerge the complete pump in a disinfectant
solution (10% chlorine bleach solution) for at
least one hour before handling the pump.
1. Before each use, inspect the general condition of the
Pump. Check for cracked or broken parts, damaged
electrical wiring, clogged Impeller Cover, Impeller,
Discharge Pipes, leaks and loose connections, and
any other condition that may affect safe operation. If
abnormal noise or vibration occurs, have the problem
corrected before further use.
Do not use damaged equipment.
2. Keep the Sewage Basin clean. Clean out the
sewage basin regularly and keep the cover in
place to keep it clean. Sand and other debris
can interfere with pump operation, can block the
air bleed hole, or can cause premature wear.
3. Clean out the air bleed hole periodically.
Quarterly Maintenance
The below maintenance must be performed at least
once every 3 months under optimal conditions.
For frequent use, or dirty areas,
more frequent maintenance is required.
1. Remove the Sewage Basin Cover.
2. Clean sludge and debris from the bottom of the shaft.
3. Rinse the housing off with clean water.
4. Clean bers from inside the pump housing
with a pressure washer (sold separately).
5. If the pump housing cannot be cleaned from
the outside, it must be thoroughly cleaned.
Unplug the power cords before maintenance.
Dismantle the bottom part of the pump as follows:
a. Remove the Screws at the bottom of the Base.
b. Remove the Base to expose the
Impeller Cover and Impeller.
c. Clean the impeller with clean water.
d. To prevent damage, do not rest the pump on
the impeller or pry against the impeller.
e. Reassemble in reverse order.
6. Make sure the oat switch can operate
freely, without obstructions.
7. Replace the Sewage Basin Cover.
Cold Weather Storage
In cold weather, when the Pump is not in use,
protect the interior of the Pump from freezing by
draining the uid and pumping a permanent type
automobile anti-freeze containing a rust inhibitor
through the system. A 50% mixture with water is
recommended. Be sure to ush the system with a
neutralizing liquid prior to re-use of the Pump.
WARNING! The oil inside some pump types
can be harmful to the environment. Check state
environmental laws before disposing any pump oil.
Parts List and Diagram
See Parts List and Assembly Diagram
for your model on included sheet.