QCells Specifications

MECHANICAL SPECIFICATION
Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
Typical module performance under low irradiance conditions in comparison to
STC conditions (25 °C, 1000 W/m
2
).
IRRADIANCE [W/m²]
RELATIVE EFFICIENCY [%]
200 400 600 800 1000
110
100
90
80
Irradiance [W/m²]
Relative efficiency [%]
Format 78.5 in × 39.4 in × 1.38 in (including frame)
(1994 mm × 1000 mm × 35 mm)
Weight 52.9 lb (24 kg)
Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reection technology
Back Cover Composite lm
Frame Anodised aluminum
Cell 6 × 12 Q.ANTUM solar cells
Junction box 3.35-4.13 in × 2.36-3.15 in × 0.59-0.67 in (85-105 mm × 60-80 mm ×
15-17 mm), Protection class IP67, with bypass diodes
Cable 4 mm² Solar cable; (+)  47.24 in (1200 mm), (-) 47.24 in (1200 mm)
Connector Amphenol H4 UTX, IP68
C-SI MODULES (L) FOR DATA SHEETS
47.24'' (
1200 mm)
39.4''
(1000 mm)
51.5'' (1308 mm)
78.5'' (1994 mm)
1.38" (35 mm)
Junction bo×
4 × Mounting slots (DETAIL A)
8 × Drainage holes 0.12 × 0.24" (3 × 6 mm)
Cable with
connectors
Frame
6 × Grounding holes, Ø 0.18'' (4.5 mm)
DETAIL A
0.63" (16 mm)
0.33" (8.5 mm)
1.0" (25.5 mm)
37.4''
(949 mm)
4 × Drainage holes 0.47 × 0.47" (11.9 × 11.9 mm)
DETAIL B
0.39" (10 mm)
0.28" (7 mm)
0.98" (25 mm)
4 × Mounting slots system Tracker (DETAIL B)
37.4''
(950 mm)
15.7'' (400 mm)
5.91''
(150 mm)
Certified
UL 1703
(254141)
PROPERTIES FOR SYSTEM DESIGN
Maximum System Voltage V
SYS
[V]
1500 (IEC) / 1500 (UL)
Safety Class II
Maximum Series Fuse Rating [A DC] 15 Fire Rating C / TYPE 1
Max Load (UL)
2
[lbs/ft
2
] 75 (3600 Pa) Permitted module temperature
on continuous duty
-40 °F up to +185 °F
(-40 °C up to +85 °C)
Load Rating (UL)
2
[lbs/ft
2
] 33 (1600 Pa)
2
see installation manual
QUALIFICATIONS AND CERTIFICATES
PACKAGING INFORMATION
Number of Modules per Pallet 29
Number of Pallets per 40' Container 22
Pallet Dimensions ( L × W × H ) 81.3 × 45.3 × 46.9 in
(2065 × 1150 × 1190 mm)
Pallet Weight 1671 lbs (758 kg)
NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use
of this product.
EFFICIENCY RELATIVE
TO NOMINAL POWER [%]
100
95
90
85
80
75
155 25200 10
YEARS
97
Q CELLS
Industry standard for tiered warranties
*
Industry standard for linear warranties
*
*
Evaluation of the 10 PV companies with the largest production
capacity in 2014 (Status: September 2014)
ELECTRICAL CHARACTERISTICS
POWER CLASS 330 335 340
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC
1
(POWER TOLERANCE +5 W / -0 W)
Minimum
Power at MPP
2
P
MPP
[W]
330 335 340
Short Circuit Current* I
SC
[A]
9.49 9.54 9.59
Open Circuit Voltage* V
OC
[V]
46.55 46.81 47.07
Current at MPP* I
MPP
[A]
8.91 8.97 9.03
Voltage at MPP* V
MPP
[V]
37.02 37.33 37.63
Efficiency
2
η
[%] ≥ 16.5 ≥ 16.8 ≥ 17.1
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC
3
Minimum
Power at MPP
2
P
MPP
[W]
244.7 248.4 252.1
Short Circuit Current* I
SC
[A]
7.65 7.69 7.73
Open Circuit Voltage* V
OC
[V]
43.44 43.68 43.92
Current at MPP* I
MPP
[A]
6.99 7.04 7.09
Voltage at MPP* V
MPP
[V]
35.01 35.29 35.56
1
1000 W/m², 25°C, spectrum AM 1.5 G
2
Measurement tolerances STC ± 3%; NOC ± 5%
3
800 W/m², NOCT, spectrum AM 1.5 G * typical values, actual values may differ
TEMPERATURE COEFFICIENTS
Temperature Coefficient of I
SC
α
[% / K] + 0.04 Temperature Coefficient of V
OC
β
[% / K] − 0.29
Temperature Coefficient of P
MPP
γ
[% / K] − 0.40 Normal Operating Cell Temperature NOCT [°F] 113 ± 5.4 (45 ± 3 °C)
IEC 61215 (Ed. 2); IEC 61730 (Ed. 1), Application class A
This data sheet complies with DIN EN 50380.
Specications subject to technical changes © Hanwha Q Cells Q.PLUS L-G4.2_330-340_2015-09_Rev03_NA
At least 97 % of nominal power during
rst year. Thereafter max. 0.6 % degra-
dation per year.
At least 92 % of nominal power after
10 years.
At least 83 % of nominal power after
25 years.
All data within measurement tolerances.
Full warranties in accordance with the
warranty terms of the Q CELLS sales
organisation of your respective country.
Hanwha Q CELLS USA Corp.
300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | WEB www.q-cells.com