User Manual
Table Of Contents
- Copyright Declaration
 - General Safety Summary
 - Safety Terms and Symbols
 - Product Scrapping
 - Contents
 - DSO2000 series digital storage oscilloscope introduction
 - 1. Quick start
 - 2. Function Introduction
- 2.1. Menu and Control Keys
 - 2.2. Connector
 - 2.3. Multi-function Knobs and Softkeys
 - 2.4. Oscilloscope Setup
 - 2.5. Horizontal Controls
 - 2.6. Vertical System
 - 2.7. Trigger System
 - 2.8. Protocol Decode
 - 2.9. Save/Recall
 - 2.10. Measure System
 - 2.11. DVM
 - 2.12. Acquire
 - 2.13. Display
 - 2.14. Utility System
 - 2.15. Fast Action Buttons
 
 - 3. Waveform Generator
 - 4. Remote Control
 - 5. Troubleshooting
 - 6. Services and Support
 - 7. General Care and Cleaning
 - Appendix A: Technical Specifications
 - Appendix B: Accessories
 - Appendix C Harmful and Poisonous Substances or Elements
 
  User Manual 
  42  /  72 
default save type  is setups.  The  saved setups, waveform  and  Ref can be  recalled  from an  USB Host 
interface on the front panel to connect an USB device for external storage. 
1. Setup   
It’s the default storage type of the scope. It saves the settings of the oscilloscope in internal or external 
memory in “.set” format. Up to 9 setting files (No.1~No.9) can be stored in the internal memory. The 
stored settings can be recalled.   
2. Wave (Binary) 
The scope saves the waveform data in memory in “.lwf” format. Up to 9 wave files (No.1~No.9) can be 
stored in the internal memory. The stored wave can be recalled.   
3. Reference 
The scope saves the waveform data in memory in “.ref” format. Up to 9 Ref files (No.1~No.9) can be 
stored in the internal memory. The stored Ref can be recalled, a total of 2 Refs can be recalled. At recall, 
the Refs will be displayed on the screen directly, at the same time, the time base, volt/div and level 
position when saving the Refs file are displayed. When the Refs is not needed, you can select “Close”. 
4. CSV   
It saves the waveform data in external memory in “.csv” format. The stored files contain the waveform 
data of the displayed channels and the main setting information of the oscilloscope. The recall of CSV 
file is not supported.   
5. Picture 
Save the oscilloscope display interface to external storage in “.bmp” format. The recall of picture file is 
not supported. 
2.9.1. Internal Save and Recall   
Taking the "Setup" file as an example, the following describes the methods and steps for saving and 
recalling. 
2.9.1.1. Save the oscilloscope setup file to internal memory.   
1. Connect the signal to the oscilloscope and obtain stable display.   
2. Press [Save/Recall] button on the front panel to enter the SAVE/RECALL function menu.   
3. Press the Save softkey and then turn the Multifunctional Knob to select Setup and then press the 
knob to confirm.   
4.  Press  the  Save  To  softkey  to  select  Internal  to  save  the  current  setup  of  the  oscilloscope to  the 
internal memory.   
5. Press the SetUp softkey button, then turn the Multifunctional Knob to select the location to save. 
The internal memory can save as many as 9 setup files, from No.1~No.9.   
6. Press the Save softkey to save the current setup to the appointed location. After a few seconds, it will 