User Manual
Table Of Contents
- Copyright Declaration
 - General Safety Summary
 - Safety Terms and Symbols
 - Product Scrapping
 - Contents
 - DSO2000 series digital storage oscilloscope introduction
 - 1. Quick start
 - 2. Function Introduction
- 2.1. Menu and Control Keys
 - 2.2. Connector
 - 2.3. Multi-function Knobs and Softkeys
 - 2.4. Oscilloscope Setup
 - 2.5. Horizontal Controls
 - 2.6. Vertical System
 - 2.7. Trigger System
 - 2.8. Protocol Decode
 - 2.9. Save/Recall
 - 2.10. Measure System
 - 2.11. DVM
 - 2.12. Acquire
 - 2.13. Display
 - 2.14. Utility System
 - 2.15. Fast Action Buttons
 
 - 3. Waveform Generator
 - 4. Remote Control
 - 5. Troubleshooting
 - 6. Services and Support
 - 7. General Care and Cleaning
 - Appendix A: Technical Specifications
 - Appendix B: Accessories
 - Appendix C Harmful and Poisonous Substances or Elements
 
  User Manual 
  17  /  72 
1.  Horizontal Offset Knob:  Used  to control  the  trigger  position  against  the  screen  center.  Push  this 
button to reset the trigger point back to the screen center. 
2.SEC/DIV Knob: Used to change the horizontal time scale so as to magnify or compress the waveform 
horizontally. If the waveform acquisition is stopped (by using the  [Run/Stop] or [Single] button), the 
SEC/DIV control will expand or compress the waveform.   
2.6. Vertical System 
2.6.1. Vertical Controls 
Vertical controls can be used to display and remove waveform, adjust vertical scale and position, set 
input parameters and perform math calculations. Each channel has a separate vertical menu to set. See 
below for menu description. 
1. Vertical Offset Knob: Move the channel waveform up and down on the screen. In dual-window mode, 
move the waveform in both windows at the same time in a same direction. Push this knob to return 
waveform to the vertical center position on the screen. Two channels correspond to two knobs.       
2. VOLTS/DIV Knob: Control the oscilloscope to magnify or attenuate the source signal of the channel 
waveform.  The  vertical  size  of  the  display  on  the  screen  will  change  (increase  or  decrease)  to  the 
ground level.   
3. Menu (CH1, CH2): Display vertical menu options; turn on or off the display of channel waveform.   
Options 
Settings 
Comments 
Coupling 
DC 
AC 
GND 
DC passes both DC and AC components of the input signal. 
AC blocks the DC component of the input signal and attenuates signals below 10Hz. 
Ground disconnects the input signal. 
BW 20MHz 
OFF 
ON 
Limits  the  bandwidth  to  reduce  display  noise;  filters  the  signal  to  eliminate  noise  and  other 
unnecessary HF components. 
Horizontal offset knob 
SEC/DIV knob 
Vertical offset knob 
Volts/DIV knob 










