Use and Care Manual
1. This heater should only be installed by a competent person. It is advised to use a qualified electrician.
2. Always disconnect the heater from the electricity supply and allow it to cool before handling or installing. Do
not install the heater on a flammable surface.
3. For ceiling mounting, the lowest part of the heater must be located at or above a minimum height of 8 ft. from
ground level, so that the heater cannot be touched when in operation.
4. For wall mounting, the lowest part of the heater must be located at or above a minimum height of 6 ft. from
ground level.
5. For both wall and ceiling mounting, there must be a distance of 24” between the heater and any adjacent walls or
corners.
6. For safe operation, the heater must be installed or placed a minimum of 3 ft. from people and activities and from
materials such as wood, carton, cloth and other flammables.
7. Always keep the supply cord away from the body of the heater which will get hot during use.
8. If the heater is installed vertically or at an angle, insure that the electrical cable is at the lower end of the heater.
9. Before drilling, ensure that there are no wires or water pipes in the area where the heater is to be installed.
10. The heater must be installed on the mounting brackets provided. Fasten the brackets securely to the mounting
surface and then to the backside of the heater using the nuts and screws supplied.
11. A weatherproof outlet with proper GFCI protection is required if the heater is ever used outside or near water or
any water source.
12. Adjust the heater angle by loosening the two bolts on the wall mounting bracket, and tighten the bolts again
when the desired angle is achieved.
13. When mounted to a wall or a ceiling, do not position the heater at an angle more than 0° (straight) or 45°
(angled). Never allow the unit to point directly at a wall surface or to point back toward the heater brackets.