Manual for 4 Pc Set with Firepit
Troubleshooting
Sudden drop
in gas flow
or reduced
flame height
Out of gas
Overfilling prevention device may
have been activated
No gas flow
Exchange, refill or replace LP gas tank
Exchange, refill or replace LP gas tank
1. Turn control knob to “OFF”
2. Wait 30 seconds and light outdoor fireplace
per “Lighting” section
3. If flames are still too low, reset the overfilling
prevention device:
a. Turn control knob to “OFF”
b. Turn LP gas tank valve to “CLOSED”
c. Disconnect regulator
d. Turn control knob to “ON”
e. Wait one minute
f. Turn control knob to “OFF”
g. Reconnect regulator and leak check
connections, being careful not to fully
open valve
h. Light outdoor fireplace per “Lighting”
section
Flame is yellow
or orange
New burner may have residual
manufacturing oils
Burn outdoor fireplace for 15 minutes and
reinspect
Spider webs or insect nest in
burner/venturi tube
Poor alighnement of the valve to
burner/venturi tube
Clean burner/venturi tube
Ensure burner/venturi tube is properly engaged
with valve
Flame goes out
High or gusting winds
Do not use outdoor fireplace in high winds
Low on LP gas
Excess flow valve tripped
Exchange, refill or replace LP gas tank
Refer to “Sudden drop in gas flow or reduced
flame height”
Flashback
(fire in venturi/
burner tube(s))
Burner and/pr burner/venturi
tube is blocked
Clean burner and/or burner/venturi tube
Flame seems
to lose heat
when burning
in cold weather
- temperature
below 50°F (10°C)
Ice has built up on the outside
of the LP gas tank because the
vaporization process is too slow
1. Turn off per “Turning Off” section
2. Replace with a spare LP gas tank
3. Reconnect LP gas tank per “Installing LP Gas
Tank” section
4. Follow “Checking for Leaks” section
5. Light outdoor fireplace per “Lighting” section
FHTS80048C
25
Irregular
flame pattern
or flame does
not run the
full length of
the burner