Manual for 4 Pc Set with Firepit
Assembly
STEP 8
Leak Test
1. Make 2-3 oz of leak detection solution by mixing one part liquid dishwashing soap with three
parts water.
2. Make sure control knobs are in the “OFF” position.
3. Connect LP gas tank per “Installing LP Gas Tank” section.
4. Turn LP gas tank valve to “OPEN ”.
5. Spoon several drops of solution, or use a squirt bottle, at all “X” locations (figure 1 and 2).
a. If any bubbles appear, turn LP gas tank valve to “CLOSED”, reconnect and re-test.
b. If you continue to see bubbles after several attempts turn LP gas tank valve to “CLOSED”
and disconnect LP gas tank, per “Disconnecting LP Gas Tank”. Contact 1-866-988-3300
for assistance.
c. If no bubbles appear after one minute, turn LP gas tank valve to “CLOSED”, wipe away
solution proceed.
WARNING: Failure to inspect this connection or not follow these instructions could cause death,
serious bodily injury or damage to property.
FHTS80048C