User Guide

24
• Turn the SET knob until the display shows the desired value.
•Turn back in measurement mode by pressing the MEA button.
Note: The internal pH and EC regulators have a small hysteresis to
prevent oscillations of the relay output that can damage the
pumps. As a result, the selected pH and EC values are equal to
the set value ± hysteresis value.
SETTING EC AND pH CONTROL TIMERS
The Timer feature is provided to avoid overdosing in a system with a long
response time. The running time of the dosing pumps is set through the
TIMER knob. The total time frame is 15 minutes. For example, if the
TIMER is set to 3 minutes, the EC or pH correction pumps will be active for
3 minutes and off for 12 minutes (3+12=15 minutes).
Setting the timer:
• In order to activate the timed dosing feature put the TIMED/CONT
switch to the TIMED position.
• To set the duty cycle of the dosing
pumps, turn the TIMER knob to the
desired position, from 1 to 10 minutes,
depending on the tank volume.
When the TIMED/CONT switch is at the CONT position, the EC and pH
correction pumps will run continuously.