User Guide
15
External fill button connection
• Connect the button
between FILL and IN-
PUT COMMON pins.
• The tank will be im-
mediately filled with
water if the external
fill button is pressed
and the water level is
below the normal level
float.
External FEED OK connection
This output is a current source from the FEED OK pin.
• Connect a LED, buzzer or other
device between FEED OK and IN-
PUT COMMON pins.
• When the water composition is good
for irrigation, the FEED OK will
source about 15mA and activate
the device.
Analog output connections
• Connect an external device between the
EC+ and EC- (for Conductivity signal) or
pH+ and pH- (for pH signal) pins.
• The output voltage is related to the value displayed on LCD. For EC the
output will be 0V for 0.00 on LCD and 5V for 10.00 on LCD; for pH the
output will be 0V for 0.00 on LCD and 7V for 14.00 on LCD.
Note: Never connect “EC” with “pH”. Make sure there is no galvanic
connection between the EC and the pH analog outputs, otherwise
the measured values will be not reliable and probes can be
damaged.
Relay connections
The controller is provided with six relay outputs (2A, 220V) protected by
2A fuses.
When a relay is off the COMMON pin is connected with the NC pin; when
is on the COMMON pin is connected with the NO pin.
The NC pin is not accessible for the pH and EC pumps and the COMMON