User Guide

14
• Place the low-level sensor to indicate the minimum water level for the
correct function of both the circulation and feeding pumps.
• Connect the sensor between INPUT COMMON and LOW LEVEL pins.
• Place the normal-level sensor to indicate the filling level when the tank
is full.
• Connect the sensor between INPUT COMMON and NORMAL LEVEL pins.
• Place the alarm-level sensor to limit the highest water level.
• Connect the sensor between INPUT COMMON and HIGH (ALARM) LEVEL
pins.
Note: The level sensors act correctly if the sensor switch is closed when the
water is above the corresponding level
Irrigation start connection
Connect the irrigation-start switch
between INPUT COMMON and IR-
RIGATION START pins.
Irrigation can be controlled by:
• using a switch connected between the INPUT COMMON and IRRIGA-
TION START: the irrigation is started by closing the switch, and lasts
until the contact is open.
• using a 5V-logic signal, connected to the IRRIGATION START and
referred to INPUT COMMON: the irrigation starts at level “0” (0V)
and stops at level “1” (5V).
• using a level sensor that will be open when the desired level is
reached: the controller will irrigate until the desired level is reached,
and the irrigation will restart if the water falls below this level.