User Guide

2524
HI762A Air probe, 1 m (3.3') cable and white handle
HI762A/10 Air probe, 10 m (33') cable and white handle
HI762BL General purpose liquid probe, 1m (3.3') cable, black
handle
HI762L General purpose liquid probe, 1m (3.3') cable, white handle
HI 762L/2 General purpose liquid probe, 2 m (6.6') cable, white handle
HI 762L/10 General purpose liquid probe, 10 m (33') cable, white handle
HI 762PBL Penetration probe, 1 m (3.3') cable, blue handle
HI762PBL/10 Penetration probe, 10 m (33') cable, blue handle
HI 762PG Penetration probe with 1 m (3.3') cable, green handle
HI762PG/10 Penetration probe, 10 m (33') cable, green handle
HI 762PR Penetration probe, 1 m (3.3') cable, red handle
HI 762PR/10 Penetration probe, 10 m (33') cable, red handle
HI 762PW Penetration probe, 1 m (3.3') cable, white handle
HI 762PW/10 Penetration probe, 10 m (33') cable, white handle
HI 762W Wire
probe, 1 m cable without handle (hard-to-reach places)
HI 762W/10 Wire probe, 10 m cablewithout handle (hard-to-reach places)
TEMPERATURE PROBESTEMPERATURE PROBES
TEMPERATURE PROBESTEMPERATURE PROBES
TEMPERATURE PROBES
When the batteries are inserted and no power adapter is connected,
the meter can recognize different batteries charge levels.
1. Fully charged batteries. The backlight and printer can be en-
abled.
2. Weakening batteries - "LOBAT" symbol blinks on LCD. The back-
light and printer are automatically disabled and it is not possible
to enable them until new batteries are inserted or an external
power adapter is connected.
3. Weak batteries - "LOBAT" symbol stays still on lower LCD. Back-
light and printer are disabled and meter can work for about 20
hours. If in Timed logging mode with the power down function
enabled this time can be longer.
4. Dead batteries - LCD shuts off. The instrument stops working to
avoid erroneous readings.
Note It is not possible to activate backlight and printer when the
instrument is in a low battery condition. If the user attempts to
enable these functions without replac-
ing the batteries or connecting the
external power adapter, the meter will
show "batt" on LCD.
Battery replacement must only take place in a non hazardous area
using 1.5V alkaline AA type batteries.
In order to replace run down batteries, sim-
ply remove the two screws on the rear cover
of the instrument and replace the four 1.5V
AA batteries with new ones, paying atten-
tion to the correct polarity.
A 12VDC power adapter can also be used to
power the unit (see the accessories para-
graph).
Note: The instrument uses the following configuration.
It is recommendable to purchase the Hanna HI710005 and HI710006
voltage adapters that use the proper polarity configuration.
However, the meters can be used with other adapters. In this case,
remember to check the correct polarity of your adapter before connect-
ing it to the meter.
+
-
BATTERY REPLACEMENTBATTERY REPLACEMENT
BATTERY REPLACEMENTBATTERY REPLACEMENT
BATTERY REPLACEMENT
3mm
0.12"
HI 762W
HI 762L
205mm
8.1"
100mm
3.9"
6mm
0.24"
HI 762A
3 mm
0.12"
205mm
8.1"
100mm
3.9"
3mm
0.12"
HI 762P
205mm
8.1"
100mm
3.9"
3mm
0.12"